CG Drives & Automation 01-7513-11r0
Faults and diagnostics
39
8.2
Diagnostics via communication interface
It is also possible to read out the status of the Emotron OSTO_100 option via a
variety of communication interfaces like e.g. Profibus, DeviceNet, Ethernet/IP,
Profinet IO, EtherCAT, CANopen etc.
The following parameter / Modbus registers shall be utilized which may also be
mapped to process data according to the Emotron fieldbus manual:
It can be read as bit 9 (0..15) in the status register on Modbus 49052. 1 <=>
STO active.
It can also be read as bit 5 (0..15) in the areaD flags on Modbus 30180. 1 <=>
STO active.
NOTE: This indication shall be treated as an unsafe output signal.