CG Drives & Automation 01-7513-11r0
Technical data
25
1)
An external 24Vdc SELV/PELV power supply must be used. This must not
be connected to any other external HW which is not related to functional
safety. It must limit the output voltage under all fault conditions to < 60Vdc.
The Emotron OSTO_100 option board input is safely designed to
withstand input voltage up to 60Vdc.
Note!
Do NOT use the generic
24Vdc output available on AC drive control board on Emotron AC drive as
this is the system voltage used both for internal and external/auxiliary
connected hardware. Further, this generic 24Vdc output is not isolated and
cascading this signal to multiple drives with possible potential difference
may cause damage to the output.
Table 4
Safety channel terminal
Terminal
Designation/function
Data
X1:1
STO1
Safety channel 1
Nominal voltage 24Vdc SELV/PELV
source
1
Logic level high >= 15Vdc
Logic level low <= 8Vdc
Input current 20 mA
X1:2
0V ref to
STO1
and
STO2
0V reference to safety channels
X1:3
STO2
Safety channel 2
Nominal voltage 24Vdc SELV/PELV
source, see footnote
1
Logic level high >= 15Vdc
Logic level low <= 8Vdc
Input current 20 mA
Содержание Emotron OSTO 100