The firescreen

 is a protective curtain of wire mesh that 

helps keep sparks and hot embers from leaving the 
firebox. The firescreen should always be kept closed 
whenever a fire is burning in the firebox.
Your fireplace may also include many of the following 
energy efficient components that provide additional 
heat output and efficient home operation:

Heat-Circulation

 adds to the standard radiant heat 

output of a traditional fireplace by distributing useful 
amounts of convective heat into the home. Heat-circu-
lating fireplaces circulate cool room air around the hot 
firebox where it is warmed and returned to the room as 
beneficial heat. The BC, BCMH, TL, SC, WMC, BFC 
and EWF Series fireplace models feature heat circula-
tion.

The Heat Exchanger

 is a multiple wall construction 

that directs room air around the firebox and back into 
the room of a heat-circulating fireplace system. Heat 
transfer from the hot fire to the circulating room air oc-
curs through these passageways. The heat exchanger 
is the heart of a heat-circulating system which provides 
the extra room heat that is lost with conventional fire-
places.

The Air Inlet/Outlet Grilles

 are part of the heat-circula-

tion system. Cool room air enters through the bottom 
grille and/or lower side inlet grilles and travels through 
the heat exchanger passageways. The resulting hot air 
is then returned to the room through the upper outlet 
grille.

NOTE: Air inlet/outlet grilles should never be cov-
ered or blocked off. The heat-circulation system 
is also used as fireplace cooling system for safe 
operation.
Outside Combustion Air:

 A fire requires a sufficient 

amount of air in order to burn properly. Insufficient air 
will cause smoking, sooting and harmful gases to filter 
out of the fireplace into the room. As the fire burns in 
the firebox, replacement air enters the firebox opening 
from the room to make up the loss of combustion air. 
Often tightly sealed and well insulated homes do not 
provide sufficient amounts of air for this natural replace-
ment process. To maintain a constant flow of combus-
tion air, direct outside air may be needed.
CFM Corporation fireplaces are designed with outside 
air capabilities which supply outside combustion air 
directly to the firebox. The air system requires ducting 
from fireplace to an outside air source at time of original 
installation. The WMC, BR, BC, BCMH, TF, TL, CR, SC, 
SHR, ODSHR, TSH, SR, ODSR, STR, TST and CVR 
Series fireplaces offer this feature as standard equip-
ment. The BFC fireplace includes integral outside air 
and no additional ducting is necessary.

If your fireplace is equipped with outside air, the control 
lever will be located at the front edge of the left side 
brick on the BR, TF, SR, ODSR, WMC, STR and TST 
Series. On the CR Series fireplaces, it is located at the 
lower left or right corner of the air inlet. On the SHR, 
ODSHR and TSH Series, the control lever is located in 
the center, just above the left side brick. Refer to Page 
6 for proper operation procedure.

Primary Air Control:

 On the EWF Series fireplace, the 

primary air control regulates the amount of heat the fire 
will produce and how long it will burn. The primary air 
control is located in the upper left corner of the unit. It 
is the primary source of air for starting, maintaining and 
reviving the fire. 
The air supply is open to the maximum when the control 
lever is rotated clockwise on the EWF36A or pushed 
down on the EWF30 and closed when rotated counter-
clockwise on the EWF36A or pushed up on the EWF30. 
To vary the burn rate, adjust the control to the desired 
position in between these extremes; opening the 
primary air control makes the unit burn hotter. Closing 
the control slows the unit down. You can adjust to any 
position you desire.

Glass Doors

 improve fireplace efficiency to help save 

home energy. When firing a fireplace, the need for 
combustion air draws room air into the firebox where it 
mixes with the hot flue gases and then is expelled up 
the open flue. The loss of preheated room air is most 
significant when burning a low intensive fire which 
normally occurs during start-up and shutdown of the 
fireplace. CFM Corporation glass doors are specially 
designed to reduce the amount of heated room air 
loss and, at the same time, allow the proper amount 
of combustion air to be filtered into the firebox for safe 
operation.
When using glass doors on a heat-circulating fireplace, 
the controlled combustion air also intensifies the heat 
exchanger temperature and slows the fuel burning rate. 
The result is maximum heating while using the least 
amount of fuel. Glass doors are standard equipment on 
WMC, BFC and EWF Series fireplaces and are offered 
as optional accessories for all other CFM Corporation 
fireplace models. Refer to proper operation procedures 
on Page 6 and 7.

Forced Air Circulation:

 Heat-circulating fireplaces use 

the natural process of hot air rising to distribute heat 
from the fireplace to the room. This principle is suffi-
cient for small room application. To distribute a constant 
flow of warm air further into a larger room, forced air 
fans are recommended. To determine if the fireplace is 
equipped with fans, use a flashlight and look through 
the lower inlet air grille. CFM Corporation offers optional 
fan kits for all heat-circulating models. For easy installa-
tion of an optional fan kit, the fireplace should be wired 

Содержание TF Series

Страница 1: ...oyer à bois BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST and WMC Series Fireplaces Save This Homeowner s Manual Conservez ce manuel du propriétaire 20000706 2 07 Rev 11 FOYERS SÉRIES BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST et WMC ...

Страница 2: ...tions 9 Maintenance and Care of Fireplace 10 Troubleshooting Guide 11 Accessories 13 Table of Contents Table des Matières Faites connaissance avec votre foyer 16 Mode d emploi de votre foyer 18 Mesures de précaution 23 Entretien et soins du foyer 24 Guide de dépannage 25 Accessoires 27 ...

Страница 3: ...t to CFM Corporation In order to validate your warranty it is mandatory that you write the serialization number a series of letters and numbers located below the model number on the warranty card The serial number is stamped into the black plate attached to the inner dome side of the firebox For better understanding of your fireplace familiarize yourself with the following parts and terminologies us...

Страница 4: ...our fireplace is equipped with outside air the control lever will be located at the front edge of the left side brick on the BR TF SR ODSR WMC STR and TST Series On the CR Series fireplaces it is located at the lower left or right corner of the air inlet On the SHR ODSHR and TSH Series the control lever is located in the center just above the left side brick Refer to Page 6 for proper operation proc...

Страница 5: ...ation is obtained in the least open position When refueling fully open damper before opening glass doors BR BC BCMH TF TL CR SR ODSR and SC Se ries Damper The flue damper is located in the dome area in the middle of the firebox The damper is opened by rotating the lever to the right The damper is closed by pushing the lever to the left and is locked closed by the damper clip located on the dome The ...

Страница 6: ...top of the other two forming a crude pyramid Be sure the irregularities of the logs form air spaces between the logs Fig 6 If they do not place a few sticks of kindling between the logs to separate them slightly Additional logs may be added as needed to maintain heat output Logs should be split preferably in quarter sections or smaller pieces Split logs have more burn ing surfaces than whole logs ...

Страница 7: ...be drawn into the firebox and expelled up the flue NOTE Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this fireplace while it is in use 4 Open Outside Air Damper Your fireplace may be equipped with outside combus tion air To determine refer to Outside Combustion Air on Page 3 If your fireplace has outside air the air damp...

Страница 8: ...ace should be operated only with the doors fully closed or fully open only when the optional spark screen is installed WARNING FIREPLACES EQUIPPED WITH DOORS SHOULD BE OPERATED WITH DOORS FULLY OPEN OR DOORS FULLY CLOSED IF DOORS ARE LEFT PARTLY OPEN GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE OPENING CRE ATING RISKS OF BOTH FIRE AND SMOKE Refer to Figure 9 for correct door positions Do not cl...

Страница 9: ...y 11 Operation of BFC36 Clean Burning Fireplace The BFC36 fireplaces have been designed specifically to reduce smoke and hydrocarbon emissions however the performance of these fireplaces depends on proper operation In order to reduce emissions use only well seasoned firewood Avoid slow burning smoldering fires and maintain a hot coal bed on which to place new wood High firebox temeratures help to ensure...

Страница 10: ...ep the bottom air inlet channel free of obstructions 7 To prevent discoloration on brass finished doors check finish for a protective plastic coating and re move if applicable 8 Do not use abrasive cleaners on glass doors 9 Do not clean while hot Maintenance and Care of Your Fireplace Your fireplace is built to operate trouble free with little need for extensive time consuming maintenance As with any...

Страница 11: ... the complete fireplace Replacement Parts Replacement parts for your fireplace can be obtained from your CFM Corporation Dealer For information on replacement parts that are available refer to installation and homeowner s manual provided with each accessory Should you need additional information beyond what your dealer can furnish contact CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L...

Страница 12: ...ing procedure Cold Air Present at Fireplace and Surround Facing If noncombustible materials brick stone marble tile etc are used to finish fireplace face inspect area between fireplace and facing material for gaps If gaps appear area must be sealed with a noncombustible ma terial to prevent cold air from entering the room Intermittent Cold Air Problems If your home is tightly sealed and well insulate...

Страница 13: ...8 or S 8 3041130 42GDKBKSR 42GDKDPSR 42GDKSSR SR42A AK MST N A 42GDKBBSR SK8 or S 8 3041130 42GDKBKSR 42GDKDPSR 42GDKSSR ODSR42A AKU1 N A 42GDKBBSR SK8 or S 8 20002230 42GDKBKSR 42GDKDBSR 42GDKSSR 42GDKSSSR STR33 AK MST N A 33GDKBB SK8 only 8 2056100 33GDKBK 33GDKDP 33GDKS STR36 CVR36 AK MST N A 36GDKBB SK8 only 8 2056100 36GDKBK 36GDKDP 36GDKS Woodburning Models Accessories for Woodburning Firepl...

Страница 14: ...STD STD S only 8 RSBG36 CR36L CR36R AK MST N A 36GCKBB SK8 only 8 RBGC36L or R BFC36 AK MST FKSX A STD S only 8 RBGBFC36 EWF36A AK MST FK26 STD S only 13 N A EWF30 AK MST FK26 STD SK or S 8 or 13 N A Accessories for Woodburning Fireplaces continued Woodburning Models Outside Air Fan Kit Glass Door Kit Chimney System1 Flue Dia Basket Grate 1 SK 2 WALL SYSTEM W 11 O D CF 2 WALL SYSTEM W 13 1 2 O D S...

Страница 15: ...20000706 15 Beaucoup de plaisir avec votre foyer à bois FOYERS SÉRIES BC BCMH BFC BR CR CVR EWF ODSHR ODSR SC SHR SR STR TF TL TSH TST et WMC ...

Страница 16: ...vert par cette dernière Remplissez la carte de garantie et postez la à CFM Home Products Pour valider votre garantie vous devez inscrire sur la carte de garantie le numéro de sérialisation série de lettres et de chiffres située sous le numéro de modèle Le numéro de série est estampé sur la plaque noire fixée sur la voûte interne du foyer Pour mieux comprendre votre foyer familiarisez vous avec les ...

Страница 17: ...entrer dans ce processus de remplacement naturel Pour maintenir un débit constant d air de combustion il faut de l air extérieur direct Les foyers CFM Corporation sont conçus pour que de l air extérieur puisse alimenter directement la chambre de combustion en air de combustion Le circuit d air nécessite la pose d un conduit allant du foyer à une source d air extérieur lors de l installation initia...

Страница 18: ...ubliez pas le registre doit tou jours être complètement ouvert lorsqu il y a un feu Registre WMC Le registre du conduit s ouvre et se ferme grâce à un bouton se trouvant juste en dessous de la grille de sortie du dessus Fig 1 Le registre est réglable et peut être ouvert partiellement du moment que les portes vitrées sont fermées et que la fumée n apparaisse pas dans l aire de combustion Le ren dem...

Страница 19: ...er avec grille Prépa rer le feu directement sur la grille Ne soulevez pas le bois Mettez une bonne quantité de papier journal froissé ou tordu sur l âtre sous la grille Laissez dépasser quelques bouts de papier de la zone des bûches pour pouvoir les allumer Disposez sur le papier du bois d allumage bouts de bois de faible diamètre en les croisant Mettez une bûche de grand diamètre sur le bois d al...

Страница 20: ...i ci ou des grilles de refoulement de circulation de chaleur Cela est dû à la cuisson de la peinture et à la combustion de l huile recouvrant le métal C est normal et disparaît après les premiers feux Si votre foyer est muni de portes en verre et d un conduit d air extérieur ouvrez les portes et fermez l arrivée d air extérieur Les odeurs et la fumée doivent être attirées dans la chambre de combus...

Страница 21: ...n sauf les modèles de série BFC EWF et WMC pour lesquels les portes doivent être complètement ouvertes pour un feu modéré Fermé Ouvert à chaud Pour un feu faible à modéré ou pour l extinction du feu les portes doivent être fermées Les foyers de série BFC EWF et WMC sont conçus pour une chaleur maximum avec les portes complètement fermées en permanence NOTE Le foyer BFC doit fonctionner uniquement ...

Страница 22: ...en ajoutant des bûches supplémentaires au besoin Utilisez un tisonnier pour rassembler les bûches en combustion en un groupe serré à l arrière du foyer chaque fois que vous ajoutez de nouvelles bûches Maintenez le lit de braise directement sous les bûches Cela aide à maintenir le feu mais ne laissez pas les cendres trop s accumuler jusqu à nuire à une circulation d air adéquate à travers les bûche...

Страница 23: ...eut aussi réduire le tirage La fermeture trop rapide du registre peut arrêter le feu ou désactiver la chambre de combustion Fermez le registre uniquement quand le feu est bien allumé Pour allumer un feu attendez qu il y ait une couche de braise d au moins 3 4 pouces avant de fermer le registre 13 Fonctionnement du EWF30 Le foyer EWF3O répond aux normes d émission établies par la US Environmental P...

Страница 24: ...rer Lorsque le bois brûle lentement il produit du goudron des vapeurs organiques et de l humidité qui se com binent pour former de la créosote Les vapeurs de créosote se condensent dans un conduit de cheminée relativement froid d une combustion lente En consé quence le résidu de créosote s accumule sur le doubla ge de cheminée Lorsque cette créosote s enflamme la combustion produit une chaleur inte...

Страница 25: ... et fabriqué pour fonctionner sans défaillance En raison de l atmosphère de l environnement résidentiel et de techniques d utilisation inappropriées vous pouvez rencontrer les anomalies suivantes auxquelles vous pouvez remédier vous même Si l anomalie ne peut pas être corrigée communiquez avec votre détaillant CFM Corporation local pour qu il vous aide Problèmes de fumée Il y a de la fumée à l all...

Страница 26: ...froid En cas d absence d isolation communiquez avec votre détaillant CFM Corporation pour connaître les bonnes méthodes d isolation Air froid au foyer et au parement de l habillage Si des matériaux incombustibles brique pierre mar bre tuile etc sont utilisés pour finir l avant du foyer vérifiez s il y a un espace dans la zone entre le foyer et le matériau du parement S il y a des espaces la zone doi...

Страница 27: ...t CFM Corporation Pour toute information sup plémentaire qui dépasse ce que votre détaillant peut vous fournir communiquez avec CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 ATT Service à la clientèle Modèles à Bois Air extÉrieur Nécessaire de ventilateur Nécessaire de porte en verre Système de cheminée Dia Du con duit Grille BC36 BC36i AK MST FK12 36GDKBB SK8 or S 8 po 30301...

Страница 28: ...0005762 52SHGDKBK seulement 52SHGDKDP 52SHGDKS WMC36 STD STD STD S SK8 8 RSBG36 WMC42 STD STD STD S 8 RSBG36 CR36L CR36R AK MST S O 36GCKBB SK8 seulement 8 RBGC36L or R BFC36 AK MST FKSX A STD S seulement 8 po RBGBFC36 EWF36 AK MST FK26 STD S seulement 13 po S O EWF30 AK MST FK26 STD SK or S 8 ou 13 po S O Modèles à bois Air extérieur Nécessaire de ventilateur Nécessaire de porte en verre Système ...

Отзывы: