SOLOY TURBINE PAC
SOLOY SUPPLEMENT NO. 2
POHS CESSNA U/TU 206G
ENGINE INLET ANTI-ICE KIT
2 of 4
F.A.A. Approved
October 4, 2005
SECTION 2
LIMITATIONS
The following information must be presented in the form of a placard
attached to the central pedestal:
1. Near alternate air control:
2. Near engine inlet anti-ice control:
SECTION 3
EMERGENCY PROCEDURES
ICING
INADVERTENT ICING ENCOUNTER
Flight into known icing conditions is prohibited. If unexpected icing
conditions are encountered, the Inadvertent Icing Encounter
checklist in Section 3 of the basic handbook should be followed. In
addition, the following procedure is recommended:
PULL ON
ENGINE INLET ANTI-ICE
OPERATION REQUIRED:
IN VISIBLE MOISTURE AT AN
O.A.T. OF 5ºC (41ºF) TO 1ºC (34ºF)
WHEN ALT AIR NOT IN USE
ALTERNATE AIR
OPERATION REQUIRED:
- IN FALLING OR BLOWING SNOW
- IN VISIBLE MOISTURE AT AN
OAT OF 1ºC (34ºF) AND BELOW
UNCONTROLLED
COPY