![CES ARi-195e Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/ces/ari-195e/ari-195e_installation-and-operation-manual_2584405020.webp)
CES SUPPORT 407-679-9440 Page
20 MAN78 ©
CES 1998
6.0
Programmable Values and Customer Record
Item
Description
Range
Representation
Default
Cust.
*
Enter Programming mode
00
Program, exit program mode
1
Alert, call, enable
0,1
0 = off, 1 = on
1
2
Alert, call, duration
0 - 255
beeps, 0 = continuous
0
3
Alert, call, relay action
0 - 2
0 = none, 1 = on with beeps,
2 = on till acknowledged
1
4
Alert, autocall, enable
0,1
0 = off, 1 = on
1
5
Alert, autocall, duration
0 - 255
beeps, 0 = continuous
0
6
Alert, autocall, relay action
0 - 2
0 = none, 1 = on with beeps,
2 = on till acknowledged
1
7
Alert, emergency, enable
0,1
0 = off, 1 = on
1
8
Alert, emergency, duration
0 - 255
beeps, 0 = continuous
0
9
Alert, emergency, relay action
0 - 2
0 = none, 1 = on with beeps,
2 = on till acknowledged
1
10
Autocall, status digit 1
0 - 16
16 = not applicable
16
11
Autocall, status digit 2
0 - 16
16 = not applicable
16
12
Clock, year
0 - 99
13
Clock, month
1 - 12
14
Clock, day
1 - 31
15
Clock, hours
0 - 23
16
Clock, minutes
0 - 59
17
Clock, seconds
0 - 59
18
Display, call queue size
1 - 20
Number of calls
20
19
Display, call queue type
0,1
0 = FIFO, 1 = LIFO
1
20
Display, suppress timer
0 - 15
min, 0 = off
0
21
Emergency, status digit 1
0 - 16
16 = not applicable
16
22
Emergency, status digit 2
0 - 16
16 = not applicable
16
23
Polarity, PTT input
0,1
0 = active lo, 1 = active hi
0
24
Polarity, speaker enable o/p
0,1
0 = active lo, 1 = active hi
0
25
RS232 port, baud rate
0 - 4
0 = 300, 1 = 1200, 2 = 2400,
3 = 4800, 4 = 9600
2
26
RS232 port, arbitration
0,1
0 = send immediately,
1 = wait for poll
0
27
RS232 port, send time, date
0,1
0 = no, 1 = yes
1
28
RS232 port, polling address
0 - 99
1