CES SUPPORT 407-679-9440 Page
13 MAN78 ©
CES 1998
18
Delay Mute
Output
Open collector, no pull up
19
Delay SCLK
Output
Open collector, no pull up
20
Delay Data
Output
Open collector, no pull up
21
Ground
22
Ground
23
Alert relay, normally open
Output
Relay contacts
24
Alert relay, normally closed
Output
Relay contacts
25
Speaker mute, common
Output
Relay contacts
4.6 Parallel/Printer Interface
Pin
Function
Direction
Signal
1
Strobe
Output
TTL open collector with 27 ohm series resistor and 10k pullup
2
D0
Output
TTL with 27 ohm series resistor
3
D1
Output
TTL with 27 ohm series resistor
4
D2
Output
TTL with 27 ohm series resistor
5
D3
Output
TTL with 27 ohm series resistor
6
D4
Output
TTL with 27 ohm series resistor
7
D5
Output
TTL with 27 ohm series resistor
8
D6
Output
TTL with 27 ohm series resistor
9
D7
Output
TTL with 27 ohm series resistor
10
Acknowledge
Input
TTL
11
Busy
Input
TTL
12
13
Selected
Input
TTL
14
15
Error
Input
TTL
16
Init
Output
TTL open collector with 10k pullup
17
Selected in
Output
TTL open collector with 10k pullup
18
Ground
19
Ground
20
Ground
21
Ground
22
Ground
23
Ground
24
Ground
25
Ground
4.7 ARi-195e Adjustments
After programming the ARi-195e and connecting the radio interface harness to the radio transceiver, attach the terminal
to the interface harness. Observe normal static prevention practices.
•
Apply power to the radio and turn the power switch on.
•
Set the service monitor to receive on the transmitter frequency. If the service monitor does not incorporate an
oscilloscope, connect an external oscilloscope to the demodulation output.
•
Using a service monitor generate a 1000 Hz signal deviated at 4.0 KHz and adjust R8 to obtain 100mvp-p at
TP1.