![CES ARi-195e Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ces/ari-195e/ari-195e_installation-and-operation-manual_2584405014.webp)
CES SUPPORT 407-679-9440 Page
14 MAN78 ©
CES 1998
5.0 Programming
Programming the unit is accomplished using
•
The internal keypad or
•
Serially using the AR
i
-2000 easi-DISPATCH software system
Internal Keypad Programming
To access the internal keypad, remove the front cover. Programming is accomplished by activating the keypad keys and
listening for the program alert tone. A chirp will be generated with each press of a key. Programming proceeds as
follows:
•
Expose the keypad by removing the right side panel and slide the keypad out from under the main PCB
•
Enter the programming mode by pressing the star key
•
The ‘done’ tone will be generated and a
P
is displayed.
•
Enter the item number to program.
•
Press pound
•
If item number is valid accept tone will be generated, and the current value displayed
•
If item number is invalid, error tone will be generated
•
Enter the new number
•
The current value is erased and the digit is displayed
•
If more than 5 digits are entered, error tone will be generated
•
Press pound
•
If data was in range, “done” tone will be generated and
P
will flash 5 times
•
If an error occurred, error tone will be generated
•
Item number and data as entered remain on the display until another key is pressed or device “program mode”
time-out timer occurs
•
To abort an entry at any time press star
•
Error tone will be generated
Programming parameters, programming:
00#
Enter this item to exit program mode. Command is executed as soon as the item number is entered, no data is
required. When executed, the done tone will be generated. Mode can also be exited by removing power or no key
activity for 2 minutes. Any exit of program mode will cause the unit to reset after the done tone is complete.
99#
Enter this item to program all locations to factory defaults. Command is executed as soon as the item number is
entered, no data is required.
Note:
The * is used to
abort
or reset an entry
The # is used to
confirm
an entry