background image

 

 

SmaRT Console Box Remote 

U093.3.0 

 

 

18 

Appendix A: Exposure to Radio Frequency Energy 

SmaRT handheld remote units contain radio transceivers. When active, a handheld remote 
sends out radio frequency (RF) energy through its internal antenna. The SmaRT handheld 
remote complies with limits set by the United States Federal Communications Commission 
(FCC) for operating distance from human tissue

.

 

Appendix B: RF Exposure Considerations 

The radio module may be used in a variety of host applications that fall into two general 
categories: 

1.  Mobile applications: Those where any operating locations are 

not

 on a human 

body. In mobile applications, the host application is typically fixed to mobile 
equipment, with either an internal or an external antenna. 

2.  Portable applications: Those where the transmitting equipment 

is

 located on the 

hand, arm, or other part of the human body. In portable applications, the 
equipment is typically held in the hand of an operator or affixed to the torso on 
either a belt or harness. 

Equipment containing the radio module was evaluated for RF exposure hazards by two 
approaches:  

1.  Maximum Permissible Exposure (MPE) for mobile applications. 

2.  Specific Absorption Rate (SAR) for portable applications. 

Required separation distances are measured from the actual location of the radiated part of the 
antenna. An antenna may be inside the host application, affixed to the enclosure of the host 
application, or at the end of an optional extension coaxial cable. 

Mobile Applications

 

Equipment must be located at least 20 cm away from areas likely to be occupied by an unaware 
person. 

Handheld Applications

 

All operators of handheld equipment with any type of antenna require proper equipment 
operation training, and such training must include RF exposure safety instructions. Once training 
is completed, they are considered 

“aware persons.” 

If the portable operating pose is on the hand or arm, a 5-mm separation is required between the 
radiating part of the antenna and nearby human tissue. 

Required Training

 

All installers and operators of host applications that include an SRF305 or SRF309 radio 
transceiver module 

must

 be trained to use proper RF safety precautions. 

Содержание SmaRT CB-xH

Страница 1: ... 2020 Cervis Inc Console Box Remotes CB xH Manual U093 3 0 ...

Страница 2: ...xempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivan...

Страница 3: ... Off 9 2 6 Associate Console Box with System Base Unit 10 2 7 Dissociate Console Box from System Base Unit 11 2 8 Proportional Output Lever and Joystick Adjustments 12 2 8 1 Enter Adjust Mode for Standard Base Unit PWM Outputs 12 2 8 2 Minimum Adjustment 13 2 8 3 Maximum Adjustment 13 2 8 4 Enter Adjust Mode for Enlarged Base Unit EBU PWM Outputs 14 2 8 5 Minimum Adjustment 14 2 8 6 Maximum Adjust...

Страница 4: ...nit 11 Figure 6 Enter Lever or Joystick Adjust Mode Standard Base Unit 12 Figure 7 Enter Lever or Joystick Adjust Mode EBU 14 Figure 8 Umbilical Connection Option and C4 20 Umbilical Kit Example 16 Figure 9 Agency Identification Label Locations 19 List of Tables Table 1 CB xH Remote LEDs 4 Table 2 CB xH Remote Operational LED Diagnostic Information 4 Table 3 CB xH Remote Console Box Specifications...

Страница 5: ... Use a damp cloth to keep units clean Remove mud concrete dirt etc after use to prevent obstructing or clogging the buttons levers joysticks wiring and switches Do not allow liquid to enter the handheld or base unit enclosures Do not use high pressure equipment to clean the handheld remote or base unit Disconnect the radio base unit before welding on the machine Failure to disconnect the base unit...

Страница 6: ... base units either standard or enlarged sizes the CB remote s ergonomic layout offers comfortable SmaRT system operation The SmaRT CB xH also offers a variety of joystick and switch options several of which are illustrated in Figure 1 that are factory configured to order The controllers provide a robust link with SmaRT base units in congested radio environments allowing seamless association withou...

Страница 7: ...eck and up to three toggle switches on either side for a possible total of 17 toggle switches A variety of pushbuttons potentiometers and rotary switches design dependent Choice of stop switch twist up or pull up Umbilical cable option available for backup or network control area network CAN control Branding Labeling Option Cervis Inc offers in house design of attractive custom labels for engineer...

Страница 8: ...nt L2 Receive RX Amber Flashes when message is received L3 Error ERR Red Lights when error occurs L4 Battery BATT Amber Low battery warning when on 2 1 V L5 L8 Custom Amber Custom optional Table 2 CB xH Remote Operational LED Diagnostic Information Condition LED Information Console Box Is Transmitting Switch Active On Console Box TX rapid blinking TX solid Low Battery BATT slow blinking M Stop Sto...

Страница 9: ...atteries soon after the first low battery warning to ensure continued reliable operation Cervis Inc recommends having fresh spare batteries on hand at all times that the system is in use The console box remote senses when the voltage is at the low power threshold approximately 2 1 V at which time the Amber battery BATT LED periodically flashes to warn you that you must change the batteries soon Th...

Страница 10: ...ase fasteners keep a single CB xH securely against your body Plus its polypropylene webbing resists wear and its bright orange color gives it high visibility against even the lightest colored garments 2 3 1 Adjusting the Harness Before you attach the harness to your CB xH adjust the blue strap to the most comfortable operating length for your individual body type The harness left strap features a ...

Страница 11: ...ds of the high visibility orange straps feature a pair of heavy duty metal button snaps at the ends To attach the harness to your CB xH locate either the two T shaped harness clips on the front of your CB one is on the left side the other is on the right or the orange bar across the top of it ...

Страница 12: ...ibility orange straps through the harness mounts or bar snap side up past the first two female snaps Fold the strap over onto itself and fasten the female snaps to their male counterparts Note You ll know the snaps are secured when you hear a clicking sound ...

Страница 13: ...ws 1 Stop Button a Twist up Stop button Release the Stop button by twisting clockwise until it pops up spring loaded b Pull up Stop button Pull the Stop button up 2 Flip the ON OFF switch S12 UP and hold it until the LEDs activate 2 5 Turn CB xH Remote Off Shut down the console box remote using any of the following methods Push the Stop switch down for immediate stop Flip the ON OFF switch S12 DOW...

Страница 14: ...be OFF and the base unit must have power disconnected Associate with the Base Unit 1 Stand near the base unit with the CB remote OFF and power removed from the base unit that is either detach cables from the base unit or disconnect the power source 2 Release the Stop switch twist up or pull up on the remote 3 Hold the Associate switch S13 UP While holding the Associate switch UP activate the CB re...

Страница 15: ... box remote OFF and power removed from the base unit that is either detach cables from the base unit or disconnect the power source 2 Release the Stop switch on the remote 3 Hold the Dissociate switch S13 DOWN While holding the Dissociate switch DOWN activate the console remote by holding the ON OFF switch S12 UP Continue to hold both switches 4 When the TX LED blinks once per second apply power t...

Страница 16: ...sets to ten seconds each time a lever or joystick is operated while in Adjust Mode Adjust each Pulse Width Modulation PWM lever or joystick using the following steps Each lever or joystick direction can be independently adjusted Figure 6 Enter Lever or Joystick Adjust Mode Standard Base Unit 2 8 1 Enter Adjust Mode for Standard Base Unit PWM Outputs 1 Release the Stop switch twist up or pull up an...

Страница 17: ... set maximum lever or joystick activation 2 8 3 Maximum Adjustment LED 7 on the standard base unit lights solid see right indicating Select Mode maximum 1 To select the maximum activation of the lever or joystick to be adjusted move the desired lever or joystick beyond 50 deflection and release it back to neutral LED 7 on the standard base unit flashes indicating Adjust Mode max To retain the curr...

Страница 18: ...lever or joystick beyond 50 deflection and release back to neutral LED 3 on the EBU flashes indicating Adjust Mode Min To retain the current minimum value flip the Adjust switch S14 UP To set the minimum to 0 flip the Associate switch S13 DOWN to store that value To adjust the current value slowly move the lever or joystick again until machine movement is initiated Continue to hold in position and...

Страница 19: ... to Select Mode Max allow the lever or joystick to return to neutral LED 2 on the base unit will light solid 2 LED 3 will go out and LED 2 will light solid after storing indicating a return to Select Mode Min Return to Section 2 8 5 to set minimum lever activation Note Activating the Associate S13 DOWN and the Adjust switch S14 UP will toggle between MIN and MAX while in Adjust Mode 2 8 7 Exit Adj...

Страница 20: ...ds are issued to the base unit through the umbilical cable Cervis Inc offers an array of umbilical kits that simplify connecting a SmaRT console box Figure 8 illustrates an example of a C4 20 Umbilical Kit that may be used in a SmaRT console box system Figure 8 Umbilical Connection Option and C4 20 Umbilical Kit Example Umbilical Power 7 V 32 V Base unit connections are determined by the specific ...

Страница 21: ...hing on transmit RX amber Flashing on receive ERR red Solid Error BATT amber Slow Blinks below 2 1 V warning approaching discharge replace batteries L5 amber L6 amber L7 amber L8 amber Custom LED color optional Custom LED color optional Custom LED color optional Custom LED color optional Enclosure Dimensions 263 5 mm x 141 5 mm x 139 mm 10 4 x 5 6 x 5 5 Durability High impact glass filled polymer ...

Страница 22: ...a belt or harness Equipment containing the radio module was evaluated for RF exposure hazards by two approaches 1 Maximum Permissible Exposure MPE for mobile applications 2 Specific Absorption Rate SAR for portable applications Required separation distances are measured from the actual location of the radiated part of the antenna An antenna may be inside the host application affixed to the enclosu...

Страница 23: ... Remote 2020 Cervis Inc 19 Appendix C Agency Identification Label Location Figure 9 Agency Identification Label Locations Note The Agency ID label for all console boxes can be found in the position shown Agency ID Label ...

Страница 24: ...del Specific Features Model Name Freq RF Power Proportional Inputs Prop Input Type Umbilical CB 9H07LV 900 MHz 10 mW 7 Single Axis Levers No CB 9H07LV UMB 900 MHz 10 mW 7 Single Axis Levers Yes CB 2H07LV 2 4 GHz 100 mW 7 Single Axis Levers No CB 2H07LV UMB 2 4 GHz 100 mW 7 Single Axis Levers Yes CB 9H03JS 900 MHz 10 mW 3 Dual Axis Joysticks No CB 9H03JS UMB 900 MHz 10 mW 3 Dual Axis Joysticks Yes ...

Страница 25: ...SmaRT Console Box Remote 2020 Cervis Inc 21 Visit our Web site at www cervisinc com 2020 Cervis Inc All rights reserved Content is subject to change without notice ...

Отзывы: