SmaRT Console Box Remote
U093.3.0
10
•
Do not activate any switch and wait for the console box Switch Inactivity Timeout to expire
(standard time is four minutes).
2.6
Associate Console Box with System Base Unit
The CB-xH remote must be associated (that is, establish a communications link) with the
SmaRT system base unit receiver before the system can be used. Systems are associated at
Cervis, Inc. before leaving the factory; but there may be times when it is necessary to Associate
while in the field. The following steps describe the Associate process.
Note: Before beginning the association process, the CB remote must be OFF and the base
unit must have power disconnected.
Associate with the Base Unit
1. Stand near the base unit with the CB remote OFF and power removed from the
base unit (that is, either detach cables from the base unit, or disconnect the
power source).
2. Release the Stop switch (twist-up or pull-up) on the remote.
3. Hold the Associate switch (S13) UP. While holding the Associate switch UP,
activate the CB remote by holding the ON/OFF switch (S12) UP. Continue to
hold both switches.
4. All LEDs illuminate for
~
1 second.
5. When the TX LED blinks at once per second, apply power to the base unit.
6. Release the Associate and ON/OFF switches (S13 and S12) when they go out.
The CB and BU
TX
and
RX
LEDs
are active, indicating that the communication link is
established.
Figure 4. Associate Console Box with Base Unit
Step 3
S14 S13 S12