background image

 

 

SmaRT 218, 918 

 

 

U053.5.1-SmaRT_OO-x18_Sys 

12 

6.0 

Specifications 

Table 2. SmaRT x18 18-Button Handheld Specifications 

Item 

Description 

Power  

V

in 

+1.6 to +3.2 VDC 

Batteries

 

Four 

“AA” cell 

Battery Life 

175 to 200 hours 

Auto-shutdown

 

15 min. of button inactivity 

Environment 

Operating Temp

 

–20° C to 55° C 
(

–4° F to 131° F) 

Storage Temp

 

–40° C to 55° C 
(

–40° F to 131° F)

 

Humidity

 

0 to 100% 

Radio 

Frequency

 

906

–924 MHz 

2405

–2480 MHz

 

900MHz RF Power 

1 mW 

2.4GHz

 

RF Power 

2 mW 

License

 

License-free

 

Modulation

 

DSSS 

Antenna

 

Internal 

Enclosure 

Dimensions 

9⅛" x 3⅛" x 1¼" 
(231.8 mm x 79.4 mm x 31.8mm) 

Total Weight 

15.2 oz. (430.9 gr.) 

Durability 

High impact polymer case 
Polycarbonate faceplate 
Stainless steel faceplate 

Indicators (6) 

LEDs 

TX (Green LED 1) 

Blinking 

– transmitting, no switch active 

 

Solid 

– button press, switch active 

RX (Amber LED 2)

  Blinking 

– receiving, no output of interest active 

 

Solid 

– base unit output of interest active 

LED 3 (Red LED 3) 

Used for Association 

Pushbuttons 

Green 

ON

 

Red 

OFF

 

1 through 16 

Function, output control 

Style 

Latching or Momentary 

Button Life 

5 million operations (typical) 

 

Содержание SmaRT 218

Страница 1: ...2020 Cervis Inc SmaRT 918 218 Remote Control System User Manual U053 5 1 SmaRT_OO x18_Sys...

Страница 2: ...rit 6 disponible sur le site Web de Sant Canada https www canada ca en health canada services environmental workplace health reports publications radiation safety code 6 health canada radiofrequency e...

Страница 3: ...urve 14 8 0 Base Unit Troubleshooting 15 List of Figures Figure 1 Standard SmaRT x18 System 3 Figure 2 SmaRT x18 18 Button Handheld Remote Control Unit 4 Figure 3 OO 218 Handheld Battery Compartment 5...

Страница 4: ...itioned or when the button is released Or in some cases when the button is pressed again SmaRT Base Unit Input output I O unit that the controlled machine is connected to SmaRT base units communicate...

Страница 5: ...e and remove power from the base unit before attempting any maintenance This will prevent accidental operation of the controlled machinery Remove power from the base unit by detaching the 12 pin cable...

Страница 6: ...uct should be recycled according to local regulations Contact local authorities for detailed information This product may be returnable to the distributor for recycling Contact your distributor for de...

Страница 7: ...unit A SmaRT system can communicate in congested radio environments using Direct Sequence Spread Spectrum DSSS wireless technology at a system dependent 900 MHz or 2 4 GHz range The system communicati...

Страница 8: ...base unit in congested radio environments The handheld remote allows seamless association to a SmaRT base unit without the need to open either unit s case The rugged weatherproof handheld enclosure al...

Страница 9: ...emove the four screws holding the battery cover in place Remove the battery cover 2 Remove the discharged batteries and properly dispose according to local regulations 3 Plug each fresh battery into a...

Страница 10: ...e typically mapped to specific base unit outputs inputs M1 through M16 as shown below Figure 4 Handheld Buttons Table 1 Handheld Button to BU I O Mapping Button BU Map M I O Channel BU Connector P and...

Страница 11: ...Red light solid 4 Continue to hold both buttons until LED 2 Amber goes out Immediately release both buttons and press Button 1 the button between the ON and OFF buttons 5 Continue holding Button 1 Ap...

Страница 12: ...Two connecting cable models are available for base unit P1 and P2 SmaRT base units feature seamless association to a SmaRT handheld unit without the need to open the case Using Direct Sequence Spread...

Страница 13: ...ses use the configuration diagrams Cervis Inc supplied as a guide Figure 7 illustrates dimensions for drilling mounting holes Figure 8 illustrates the wiring harness connections Figure 7 Internal and...

Страница 14: ...tton 3 10 M2 button 2 9 M1 button 1 3 M7 button 7 7 VDC 2 M6 button 6 7 M13 button 13 6 M12 button 12 5 M11 button 11 4 M10 button 10 3 M9 button 9 2 UNUSED 1 VDC NOTE VDC Battery Power Supply Positiv...

Страница 15: ...em 2020 Cervis Inc 11 Figure 9 Field Wiring Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Field Load Fi...

Страница 16: ...GHz RF Power 2 mW License License free Modulation DSSS Antenna Internal Enclosure Dimensions 9 x 3 x 1 231 8 mm x 79 4 mm x 31 8mm Total Weight 15 2 oz 430 9 gr Durability High impact polymer case Pol...

Страница 17: ...cceleration 10 0 g peak shock acceleration INDICATORS 5 In Green Input On Out Green Output On Health Green Pulse sec OK TX RX Green Receive Red Transmit Power Amber OK Red Green Fault ENCLOSURE Dimens...

Страница 18: ...SmaRT 218 918 U053 5 1 SmaRT_OO x18_Sys 14 7 0 BU x16F Output Current Derating Curve Figure 10 Base Unit Output Current Derating Curve...

Страница 19: ...mal condition Out LED pulsing Amber Indicates an over current condition Out LED slowly pulsing Amber Over temperature indication In LED not active Check to make sure that voltage to channel is less th...

Страница 20: ...t www cervisinc com The Cervis Inc and SmaRT Wireless logos are trademarks of Cervis Inc Contact via Phone 724 741 9000 2020 Cervis Inc All rights reserved Content is subject to change without notice...

Отзывы: