Before Start Up
Keep heater area clear and free from combustibles,
flammable liquids and chemicals.
Pool water must be flowing through the Heater and the
Heater pressure gauge showing between 1.5 to 2.5 bar
for it to operate.
Quick Start
Check that the Electricity and Gas Supplies are on.
Turn on the Pool Pump. Turn on the Heater with the
switch on the Front Panel and set the desired
temperature with the Pool Temperature Knob. In a
few seconds the Heater will fire.
Summary of Controls
(Left to Right)
Pressure Gauge -
This should be between 1.5 to
2.5 bar, repressurise if too low.
ON/OFF Switch -
Turns the Heater On and Off.
Lock/Reset Button
-
If it is pressed for 2 seconds
it locks the Set Temperature so the Pool Tempera-
ture Knob is inoperative. To unlock, press again for 2
seconds. When locked a short press flashes the Set
temperature.
It also resets Gas Control lockouts, GAS and OH2.
Pool Temperature Display
-
This normally
shows the Pool Temperature but also show the
Setting Temperature when the Pool Temperature
Control Knob is moved. The Display is also used for
commissioning and diagnostic purposes.
(Page 16)
If the display alternates the temperature with ‘SEr’ it
is recommended that the Heater is serviced, it will
continue to function.
Condensing Pool Heater
1
22/12/08
Genie
USER'S OPERATING INSTRUCTIONS
FOR YOUR SAFETY - READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
This appliance is equipped with an ignition device
which automatically lights the burner.
BEFORE OPERATING after a prolonged time off,
smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
* Do not try to light any appliance
* Do not touch any electric switch
* Do not use any phone in your building.
* Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
* If you cannot reach your gas supplier,
call the fire service.
* Isolate the appliance with the Service
Cock inside. If this is not accessible,
isolate at the gas meter.
* Do not use this appliance if any part
has been under water. Immediately
call a qualified service engineer to
inspect the appliance and to replace
any part of the control system and any
gas control which has been damaged.
CAUTION:
Propane gas is heavier than air and
will settle on the ground. Since it can accumulate
in confined areas, extra care should be exercised
when lighting Propane heaters.
WARNING:
There are no user servicable items in
this appliance. Do not interfer with any sealed
components.
MPORTANT INFORMATION
Incorrect water balance will cause premature
failure of this heater. Such damage is not covered
under warranty. For additional information please
see page 3 of these Instructions.
On/Off Switch
Reset/Lock
Button
Temperature
Display
Pool Temperature
Control Knob
Pressure
Gauge
Содержание MB35S
Страница 24: ...Fig 11 0 Condensing Pool Heater 21 22 12 08 Schematic Wiring ...
Страница 33: ...Condensing Pool Heater 30 22 12 08 This page has been intentionally left blank ...
Страница 34: ...Condensing Pool Heater 31 22 12 08 This page has been intentionally left blank ...
Страница 36: ...Station Lane Industrial Estate Witney Oxon Tel 01993 778855 Fax 01993 703407 22 12 08 ...