Fault Codes
Condensing Pool Heater
23
22/12/08
DISPLA
Y
LOCK / RESET
GREEN
YELLOW
RED
LED1
RED
RED
LED2
Running, raising pool temperature to 28°C
Up to temperature, 28°C
Insuf
ficient water pressure. Filter?, Blockage?
‘OH2’
Flue gas over temperature.
Allow to
cool then investigate in Engineering Mode.
Reset with Button
‘GAS’ Gas Control Lockout. Unable to light
burner
, reset with Button.
OR
Flue S
tat tripped.
Investigate cause. Reset on Flue S
tat
FRONT P
ANEL
ON PCB
EXPLANA
TION
OFF
, no mains supply or failed power supply
Flashing
‘HI’ Condensate level high. Blocked? Clear
obstruction and allow control to auto reset .
‘SEr
’ alternating with pool temperature. Serv-
ice required, working hours has reached
setpoint.