Maintenance
The purpose of the maintenance and adjustment schedule is to keep the
generator in the best operating conditions.
Inspect or service as scheduled in the table below.
Note
: Shut off the engine before performing any maintenance. If the engine must
run during it, make sure the area is extremely well ventilated. The exhaust does
contain poisonous carbon monoxide gas.
Maintenance Schedule
Regular service period (1)
___________________________
Item operation to perform
Each Use
First month or
20 hours
Every 3
months or 50
hours
Every 6
months or 100
hours
Every year or
200 hours
Engine oil
Check level
●
Change
●
●
Air cleaner
Check
●
Clean
(2)
●
Spark plug
Check / adjust
●
Combustion chamber Clean
●
Valve clearance
Check / adjust
(3)
●
Fuel tank and filter
tank
Clean
(3)
●
Fuel line
Check
Every 2 years – replace if necessary (3)
1.
Log hours of operation to determine proper maintenance.
2.
Service more frequently when used in dusty areas.
3.
These items should be serviced by a qualified technician, unless the owner has the proper tools and is
mechanically proficient.
Temperature (°C)
Time between oil changes (hour)
Recommended Power Factor
25
Normal
100%
30
18
95%
35
15
85%
40
12
70%
Note
: if the temperature of the external environment reaches 45°C or higher, the
generator should not be used, as it may be damaged. If the external
environment reaches -5°C or lower, the generator should not be used.
Changing Oil
Drain the oil while the engine is still warm to ensure rapid and complete draining.
Note
: make sure to turn the engine switch and the fuel cap vent lever OFF before
draining the oil.
1. Lean the generator to the side.
2. Fasten the oil lead pipe onto the oil exhaust as shown in the picture
overleaf. Then pour out the oil.
3. Refill with new oil and check the oil position in the crankcase.
4. Once the crankcase has new oil in it, please gently shake the generator
from left to right a few times to ensure that the bobber used for the oil
alarm system is floating.
15
Содержание CTINV35GENA
Страница 1: ......