background image

Never use an oil/petrol mixture or dirty fuel.

Avoid getting dirt, dust or water in the fuel tank.

After refuelling, tighten the fuel filler cap securely.

Petrol is extremely flammable under certain conditions.

Refuel in a well-ventilated area with the engine stopped.

Do not smoke or allow flames or sparks in the area where the engine is 
refuelled or where petrol is stored.

Do not overfill the fuel tank. After refuelling, make sure that the tank cap is 
closed properly and securely.

Be careful not to spill fuel when refilling. Spilled fuel or fuel vapours may 
ignite. If any fuel is spilled, make sure the area is dry before starting the 
engine.

Avoid repeated or prolonged contact with skin, or the breathing of vapour.

KEEP FUEL OUT OF REACH OF CHILDREN

Check the Air Cleaner

Check the air cleaner element to ensure it is clean and in good working condition.

1. Loosen the cover screw and remove the left side maintenance cover.
2. Press the latch tab on top of the air cleaner body, remove the air cleaner 

cartridge, then check the element.

3. Clean and replace the element if necessary.

Never run the engine without the air cleaner. Rapid engine wear will result from 
airborne contaminants such as dust and dirt being drawn through the carburettor
and into the engine.

It is normal for a little oil to appear under the air filter box if the generator is 
running for a long period of time or if a lot of oil is in the engine. Wipe up excess 
oil after each use and after stopping the generator.

5

Fuel Cap

Open

Air Cleaner 
Cartridge

Air Cleaner
Case

Screws

Access Panel
Screws

Access Panel

Air Cleaner
Element

Содержание CTINV35GENA

Страница 1: ......

Страница 2: ...remely flammable and is even explosive under certain conditions Refuel unit in a ventilated area with the engine stopped WARNING Keep away from cigarettes smoke and sparks when refuelling the generator Always refuel in a well ventilated location WARNING Connecting the unit to a building electrical system as a standby power source must be performed by a qualified electrician The connection must iso...

Страница 3: ...rator Use 9 AC Applications 10 Output and Overload Indicators 10 DC Applications 12 Starting the Engine 13 Oil Alert System 13 Stopping the Engine 14 Maintenance 15 Maintenance Schedule 15 Changing Oil 15 Air Cleaner service 17 Spark Plug Servicing 17 Transporting and Storage 18 Transporting the generator 19 Before storing the unit for an extended period 19 Muffler Fire Net Service 19 Troubleshoot...

Страница 4: ...ntial hazards that can cause serious injury Read the labels and safety notes and precautions described in the manual carefully 3 Air Vent Knob Fuel Cap Top Maintenance Cover Control Panel Starting Grip Muffler Cover Fuel Valve Primer Bulb Maintenance Access Overload Indicator Light Output Indicator Light Oil Alert Indicator Light Eco Throttle Switch Engine Switch DC Socket DC Circuit Breaker Groun...

Страница 5: ...t in If the oil level is below the end of the dipstick refill up to the top of the oil filler neck Note The Oil Alert System will automatically stop the engine before the oil level falls below the safe limit however to avoid the inconvenience of an unexpected shut down it is still advisable to visually inspect the oil level regularly Checking the Fuel Level Turn the fuel cap lever to the OFF posit...

Страница 6: ...athing of vapour KEEP FUEL OUT OF REACH OF CHILDREN Check the Air Cleaner Check the air cleaner element to ensure it is clean and in good working condition 1 Loosen the cover screw and remove the left side maintenance cover 2 Press the latch tab on top of the air cleaner body remove the air cleaner cartridge then check the element 3 Clean and replace the element if necessary Never run the engine w...

Страница 7: ...t Power W The format is XXXX X W integer Oil Fuel Invalid Time Running Time Displays the total running time The format is xxx xx xx hr m sec Overload Oil Sensor light Overload The LCD screen will display the current output when the generator is running normally When the generator is overloaded or short circuited the generator will not supply power to appliances The voltage current and frequency wi...

Страница 8: ...e started by using the starting key remote control Use the starting key not the remote controller to stop the generator when the generator has been started by the starter key Use the remote controller not the starting key to stop the generator when the generator has been started by the remote control The emergency stop button can be used to stop the generator at all times no matter which method wa...

Страница 9: ...tly on the start cord until you feel resistance then yank hard and swiftly Do not let the start cord retract by itself but instead guide it back by hand Hold the carry handle firmly to prevent the generator from falling over when you pull the start cord Note A hot motor will not start if there is too much fuel in the cylinder If this happens wait for five to ten minutes before trying again 8 Fuel ...

Страница 10: ...carburettor is jetted for may result in reduced performance overheating and serious engine damage caused by excessively lean air fuel mixture Generator Use To prevent electric shock from faulty appliances the generator should be grounded Connect an electric conductor cable of at least 1 5mm2 between the generator s ground terminal and an external ground source Connections for standby power to a bu...

Страница 11: ...r is overloaded or there is a short in the connected appliance the output indicator light will go OFF the overload indicator light red will go ON and current to the connected appliance will be shut off Stop the engine if the overload indicator light goes ON and investigate the overload source Note Before connecting an appliance to the generator check that it is in good working order and that its e...

Страница 12: ...up In the event of overload the output indicator light will go out and the overload indicator light will come on No power will be output however the engine will not have stopped so the engine must be stopped by setting the respective engine switch to STOP Note When equipment requires a large starting power the overload indicator light and the output indicator light may light together for a short t...

Страница 13: ...Charging must be stopped once the voltage of the batteries is above 16V or it may cause the battery to explode causing serious injury or death To prevent the possibility of creating a spark near a battery connect the charging cable to the generator first then to the battery Disconnect the cable first at the cable Before connecting charging cables to a battery that is installed in a vehicle disconn...

Страница 14: ...r milk then follow with milk of magnesia or vegetable oil Call 000 KEEP OUT OF REACH OF CHILDREN PETS AND UNTRAINED PERSONS Starting the Engine The DC receptacle may be used while the AC power is in use An overloaded DC circuit will trip the DC circuit protector If this happens disconnect the DC load before pushing in the circuit protector to resume operations Oil Alert System The oil alert system...

Страница 15: ...nserted plug out 2 Turn the engine switch to the OFF position 3 Turn the cap lever fully counter clockwise to the OFF position Note Be sure that both the fuel cap lever and the engine switch are in the OFF position before stopping transporting and or storing the generator 14 Plug Engine Switch Turn the fuel valve knob to the OFF position Open Close Air Vent Knob ...

Страница 16: ...Service more frequently when used in dusty areas 3 These items should be serviced by a qualified technician unless the owner has the proper tools and is mechanically proficient Temperature C Time between oil changes hour Recommended Power Factor 25 Normal 100 30 18 95 35 15 85 40 12 70 Note if the temperature of the external environment reaches 45 C or higher the generator should not be used as it...

Страница 17: ...mpatible with the environment We suggest that you transport it in a sealed container to your local service station or municipal waste disposal facility for reclamation DO NOT dispose of it in the trash pour it on the ground or pour down a sink or into a stormwater drain 16 Generator Oil Drain Pipe Oil Container Dipstick Lowest oil Level allowed ...

Страница 18: ... cartridge down 30mm and remove the air filter cartridge 4 Remove the air filter iron clip and check the air filter element Clean or replace the element if necessary 5 Reinstall the air filter parts after cleaning or replacing the air filter element Spark Plug Servicing Please use high quality spark plugs for best performance To ensure proper engine operation the spark plug must be properly gapped...

Страница 19: ... Note the spark plug must be securely tightened An improperly tightened plug can become extremely hot and may damage the generator Never use a spark plug with an improper heat range Never use a spark plug without damping resistance or it will cause no AC output Transporting and Storage To prevent spillage when transporting or during temporary storage the generator should be secured upright in its ...

Страница 20: ...2 Drain the fuel Note fuel is extremely flammable and explosive under certain conditions Do not smoke or allow flames or sparks in the area 3 Completely drain the fuel from the tank Open the fuel valve start the engine and operate in the idle position until all remaining fuel is gone and the engine stops automatically 4 Discharge the oil 5 Remove the spark plug and fill the cylinder with 2cc s of ...

Страница 21: ...at rise if the generator cannot start after adding oil for the first time and the oil alarm indicator stays on when pulling the starting grip Make sure there is no spilled fuel around the spark plug Spilled fuel may ignite If the engine still doesn t start contact the Kogan customer support team for further assistance Inspection 1 Remove the spark plug rubber boot and clean any dirty from around t...

Страница 22: ...or won t start Is the output indicator on No Is the overload indicator on No Contact the Kogan customer support team Yes Does the electrical equipment work when plugged in directly No Restart after turning off the overload indicator Yes Yes Replace or repair the electric equipment Contact the Kogan customer support team There is no power in the DC electric outlet Is the electric circuit breaker in...

Страница 23: ...witch is off Cooling system Forced air cooling Ignition system T D I Oil capacity L 0 45 Fuel tank capacity L 7 Spark plug NGK 4629 C7HSA Noise level 94 dB A Continuous operation 5 5h Generator AC output Rated voltage V 230 Rated frequency Hz 50 Rated current A 18 16 8 7 Rated output KVA 2 Maximum output KVA 2 7 DC output For 12V automotive batteries only Rated voltage V 12 Rated current A 8 3 22 ...

Отзывы: