Cermetek Microelectronics, Inc. 

High Speed Internet Modem Family 

 

 

2005 Cermetek Microelectronics, Inc. 

Page 3 

Document No. 607-0017 Revision I1 (05/05)

 

iMODEM EVALUATION BOARD 

Cermetek manufactures a companion evaluation board 
that is designed to simplify the hardware connections 
required to program the iModem as well as providing a 
reliable platform to assist with system level debugging.  
Contact Cermetek and ask for the CH21XX iModem 
Evaluation Board. 
 
 

iMODEM CONTROL METHODOLOGIES 

The iModem receives 

@T

®

 commands from the host 

processor or receives an event status flag on the Send 
Email Control Pin (Pin #6) and proceeds to dial up the 
local POP, log on to the internet, authenticate and verify 
the user ID and password, and either sends or retrieves 
email depending on the command/status flag received.  
For CH2124/60 products, see Table 1 for a summary of 
available 

@T

®

 commands. 

 
The iModem Family offers a variety of internet 
communication features ranging from simple on 
demand event triggered email transmission to full send 
and retrieve email capability.  User Control of the 
internet communication activity of the iModem device 
typically falls into one of the following basic control 
strategies: 
1. Fully Autonomous or event driven pin control 

requiring no host processor intervention.  A pre-
stored message is sent on a pin transition 
(CH2124/60). 

2.  Semiautonomous control, requiring one command to 

be issued from the host processor.  A pre-stored 
message is sent on command. 

3.  Complete host intervention and supervision requiring 

each command to be issued from the host. 

 

Message is constructed and sent in real time. 

 

Fully Autonomous On Demand Event Driven 
Control.

  This is the simplest method of operational 

control.  Application of a 50ms TTL Low going pulse or 
level to the Send Email Control pin (Pin # 6) will cause 
the CH2124/60 iModem to send an email using its 
internal internet configuration profile.  This profile is pre-
programmed at the factory and can be modified by the 
user as necessary.  No host processor intervention is 
required.  The DTE serial interface is not required for 
fully autonomous on demand or event driven control.  
The CH2124/60 iModem will abort email related 
activities and return to the idle state if a low going TTL 
pulse is presented to the SEND Email Control Pin (Pin 
# 6) at any time during or after initiation of email send. 
 

Semi-Autonomous Control.

  This method requires a 

minimal amount of host processor intervention and 
requires that the DTE serial port be operational.  Semi-
autonomous control is a special case of full Host 
Supervised Control and relies on the preprogrammed 
default internet configuration profile contained within the 
iModem.  Initiation of an email activity occurs with the 
issuance by the host processor to the iModem the 
appropriate

 @T

®

 

command to send/retrieve/delete 

email.  PSTN dial-up, logon, authentication and email 
transmission, retrieval, and/or deletion are performed 
automatically by the iModem in the same fashion as for 
the Fully Autonomous On-Demand control method 
described above. 
 

Host Supervised Control.

  This method is the most 

flexible, but requires issuance by the host processor of 
the necessary 

@T

®

 commands in the required order 

from the host processor.  When choosing an 
implementation scheme utilizing a host processor, the 
host controls the iModem by using Cermetek 

@T

®

 

commands.  These commands are similar to the 
standard Hayes AT command set. 
 
Although the DTE serial port is required to be 
operational for this method of control, an additional 
feature of this method is the ability of the host to over-
ride the preprogrammed parameters (including the 
email message content) by simply entering the 
applicable information using the appropriate 

@T

®

 

Command. 
 

Delete Email.

  The user may selectively delete any 

email message (by specifying the message number) or 
delete all messages cached on the POP3 server. 
 

Email and Internet Activity Status.

  The CH2124/60 

provides activity status messages on the iModem’s 
serial port.  These status messages consist of a series 
of ASCII characters.  Some examples are: BAD 
MESSAGE NUMBER, CONNECT, HANGING UP, 
MESSAGE ACCEPTED, MESSAGE DELETED.  For a 
more detailed discussion of CH2124/60 status 
messages, refer to Cermetek Application Note # 155, 

@T

®

 Command Set Description and Usage For 

CH2124/60 iModems. 
 

Back-up and Alternative POP access Phone 
Numbers.

  Cermetek iModem products allow usage of 

an alternative local access POP phone number or, if 
available, a 1-800 number, should the iModem fail to 
connect to the primary POP.  The user can establish 
the number of attempts made to the primary POP 
before the back up POP is attempted. 
 

Содержание CH2124

Страница 1: ...d available free of change INTRODUCTION Direct machine to machine interaction represents the next logical extension of the internet Cermetek internet modem iModem products are designed to exploit the internet to facilitate the utilization of machine to machine interactions Using email information can easily be transferred between systems and can be transmitted retrieved at will Internet email prov...

Страница 2: ...H2124 iModem contains a fully functional 56kbps 2400bps modem and the hardware and firmware needed to provide the internet capability Because of the unique architecture of Cermetek iModems these iModems have the ability to operate as either an internet email transceiver or as a high reliability analog modem Additionally the CH2124 60 products support user remote access which can be used to reprogr...

Страница 3: ... the idle state if a low going TTL pulse is presented to the SEND Email Control Pin Pin 6 at any time during or after initiation of email send Semi Autonomous Control This method requires a minimal amount of host processor intervention and requires that the DTE serial port be operational Semi autonomous control is a special case of full Host Supervised Control and relies on the preprogrammed defau...

Страница 4: ...nds an ASCII MESSAGE ACCEPTED activity response message and sends a TTL LOW Pulse to Pin 8 indicating that the ISP Mail Server has accepted the email message Control of the internet capabilities of the iModem can be either event driven or initiated and controlled by a system level host processor Refer to Table 3 for a complete set of pin descriptions When not utilized in the internet connectivity ...

Страница 5: ...on with the internal µP controller Refer to Application Note 158 Cermetek iModem Caveats and Definitions for a more detailed discussion of this issue IMPORTANT NOTE Cermetek recommends a minimum of 50ms inter character delay when sending commands to the CH2124 60 iModem Failure to do so could result in unpredictable performance Refer to Cermetek s High Speed Modem and FAX Family product data sheet...

Страница 6: ...ware versions 1 262 or greater T J 1 1 2 7 12 Establish email message type to be sent when iModem SEND pin is activated or the TD command issued J1 will select the User Defined message or by K8 parameter for firmware versions 1 262 or greater T K0 n 1 2 6 Select PAP Authentication Protocol n 01 allows PAP only DEFAULT n 7D allows CHAP or PAP CHAP NOT SUPPORTED T K1 n 1 2 6 Set the number of dial u...

Страница 7: ...is currently limited to 125 ASCII characters Blanks or spaces are allowed and count as 1 character per each occurrence The entered message is stored in message memory location M1 T N1 n 1 2 Enter local access phone number for ISP n T OP1 n 1 2 Enter POP3 server IP HEXIDECIMAL address n T OS1 n 1 2 Enter SMTP server IP HEXIDECIMAL address n T PW n 1 2 Enter Dialup Password Maximum length is 15 alph...

Страница 8: ...5 Parameter must be specified as one ASCII alphanumeric character 6 Parameter must be specified as two alphanumeric characters Use a leading 0 if necessary 7 Effective with iModem Firmware Revisions 1 262 or greater the TJ0 and TJ1 commands have been replaced with K8 parameter modifiable with the TK8 command 8 Dial up Unix Shell account access is NOT currently supported on the iModem Network ISP 9...

Страница 9: ...curs after successful email transmission and after receipt of MESSAGE ACCEPT status from ISP SMTP mail server MESSAGE DELETED 1 Occurs after successful deletion of specified message number s NO CONNECT 1 Occurs when PSTN line is released after unsuccessful dialup and or unsuccessful ISP negotiation and or unsuccessful SMTP server negotiation NO DIALTONE 1 Occurs after unsuccessful dialup and iMode...

Страница 10: ...y User Defined email message TN1 Display local access POP phone number TOP1 Display POP3 server IP address TOS1 Display SMTP server IP address TPW Display Dial up password TPM Display POP3 password TP1 Display ISP password TS1 Display email subject TU1 Display email recipient TO name Commands To Interrogate iModem Command Function TI Display iModem product type and firmware revision TV Displays IS...

Страница 11: ...rovable for use by DOT to Industry Canada CS 03 Part I However per Canadian procedures approval can only be granted after the iModem has been installed into the end product Typically Canadian approval is obtained by submitting the final end product to an independent test house or consultant for evaluation The test house consultant then forwards the test results and applicable documents to the regu...

Страница 12: ...o the users or the operation of the user s equipment the telephone company will give the user notice in writing to allow the users to make any changes necessary to maintain uninterrupted service In certain circumstances it may be necessary for the telephone company to request information from the users concerning the equipment which the user has connected to the telephone line Upon request of the ...

Страница 13: ...nary 1 condition is indicated by a HIGH 11 RXD O RECEIVE DATA Serial Receive data output Received marking or a binary 1 condition is indicated by a HIGH 12 NC NO CONECTION 13 DTR I DATA TERMINAL READY INPUT Active LOW Switching off DTR can either return modem to command state disconnect phone call or reset modem DTR should be set LOW when not in use 14 DSR O DATA SET READY LOW indicates handshakin...

Страница 14: ...o verify compliance For Canada use either 10Ω resistors carbon film or SMD parts 1 8 watt minimum as described in paragraph B above 2 Over Voltage and Lightning Protection A Surge Protection is provided by internal circuitry see Figure 3 No additional external components are required to maintain conveyed FCC Part 68 approval B In most environments 2 terminal surge suppressors are adequate For seve...

Страница 15: ...roducts Model Summary of Features Operating Temperature CH2124 2 Input Sense Pins Send and Retrieve Emails Email Send Control Pin Full Function V 22bis 2400bps FCC Part 68 Approved UL1950 listed 0 C to 70 C CH2160 2 Input Sense Pins Send and Retrieve Email Email Send Control Pin Full Function V 90 56Kbps FCC Part 68 Approved UL 1950 listed 0 C to 70 C Figure 4 Example Circuit for illumination of E...

Страница 16: ...nput Current RST 580 uA CP Capacitive Load TXD DTR RTS Capacitive Load RTS 10 8 pF pF Table 6B CH2160 iModem Electrical Specifications Symbol Characteristic Min Typ Max Units VCC Positive Supply Voltage 4 5 5 0 5 5 V ICC Off Hook Nominal Operating Current VCC 5 5V when modem is Off Hook 120 0 mA VIH High Level Input Voltage 5 0V 2 0 3 5 V VIL Low Level Input Voltage 5 0V 1 0 2 2 V VT Positive Hyst...

Страница 17: ...lse 10 msec If user supplied Note 1 All CH2124 iModem devices perform an internal self check upon reset and will not respond to commands issued during this self check sequence Table 7B CH2160 iModem Electrical Specifications Parameter Minimum Typical Maximum Units Comments Off Hook Impedance 20 Mohm Trans Hybrid Loss 25 dB 600 Ohm RXA TXA Ring Voltage Loop 35 VPP On 48VDC line voltage for sustaine...

Страница 18: ...e or for any infringements of patents or other rights of third parties resulting from its use No license is granted under any patents or patent rights of Cermetek Cermetek provides the user with a FCC USA and IC Canada Approved or Approvable device However Cermetek does not have influence over nor knowledge of the specific user application environment Therefore for FCC and IC Approved or Approvabl...

Отзывы: