
Installation Guide for FibeAir IP-20G, FibeAir IP-20G Assured
Page 45 of 49
Ceragon Proprietary and Confidential
•
The main traffic connections are correctly terminated and crimped as per
cable and connector manufacturer instructions. All fiber optic patch leads
should be routed carefully and efficiently, using conduits to prevent damage
to the cables.
•
All other user terminations are secure and correctly terminated.
•
All labeling is complete as per site requirements. Labeling is specific to each
customer. At a site with only one installation, labeling may be unnecessary.
However, at sites with multiple installations, correct and adequate labeling is
essential for future maintenance operations.
Typical labeling requirements include:
Antenna labels - for link identity and bearing
RFU labels - for link identity, frequency, and polarization
Coax cable labels - for link identity, close to the RFU, IDU, and either end of any
joint
IDU labels - for link identity