background image

CEP AG

Revision 1.2

_________________________________________________________________________________

__________________________________________________________________________________________

Page 2 of 28

Important information

This technical description contains important information for start up and use of the GT864-QUAD/PY
Terminal. Read it carefully before you start working with the GT864-QUAD/PY Terminal.
The warranty will be void should damage occur due to non-compliance with these instructions for use.
We cannot accept any responsibility for consequential loss.

We cannot be held responsible for material loss or personal injury that is due to incompetent use or
non-compliance with the safety instructions. The warranty will be void in such circumstances.

The GT864-QUAD/PY Terminal contains highly integrated components which can be damaged by
electrostatic discharge if the user would open the housing.

Therefore only touch the GT864-QUAD/PY Terminal on the housing or
connectors and avoid touching the components on the board.

Safety Instructions

When using products which are exposed to electric voltage the valid
regulations have to be observed.

Before opening of a device always pull the mains adapter or make sure that the device is
disconnected from the power supply.

You should only use tools on components, modules or devices if they are disconnected from the
power supply and the electric charge, which may still be stored in some components, inside the device
has been discharged.

All cables and wires which are energized and connected to the device, the module or components
have to be checked regularly for any damage of the isolation shield or fractures of the cables. If the
supply cables are visibly damaged the device has to be taken out of operation immediately until the
faulty cable has been exchanged.

When using components or modules it is necessary to strictly observe the specification given in the
corresponding description of these components. If a description for a private end-customer not clearly
states which electric data is valid for a component or a module, how to wire the device, which external
components or additional devices can be connected or which parameters these components are
allowed to have, a specialist must be contacted.

Before putting a device into operation, it has to be clarified, whether this device or module is meant for
the field of application. In case of doubt ask specialists or the manufacturer of the device.
Please note that we are not responsible for any errors in usage or connection. Therefore we cannot
accept any responsibility for consequential loss.

Devices which operate with >35 Volt have to be connected by a specialist. Before putting the device
into operation it should be checked that there is no current leakage on the housing.

In case those measurements with the opened housing are necessary, an isolating-transformer has to
be integrated for safety reasons. Alternatively the voltage can be supplied by an appropriate power
supply which complies with the safety regulations. All wiring work has to be done in a voltage free
state only.

Содержание GT864-PY

Страница 1: ...___ __________________________________________________________________________________________ Page 1 of 28 GT864 QUAD PY Terminal Technical Description Rev 1 2 CEP AG Raiffeisenallee 12b 82041 Oberha...

Страница 2: ...ponents inside the device has been discharged All cables and wires which are energized and connected to the device the module or components have to be checked regularly for any damage of the isolation...

Страница 3: ...ng states LEDs 14 3 3 1 Power up LED green LED in the middle 14 3 3 2 Status LEDs one yellow one red 14 4 Power consumption 15 Safety and Product Care 16 4 1 Safety instructions 16 4 2 General precaut...

Страница 4: ...show the mechanical design of the GT864 QUAD PY Terminal along with the positions of the different connectors and mounting holes The GT864 QUAD PY Terminal case is made of durable PC ABS plastic Plea...

Страница 5: ...ly bolt the modem into your application Keypad display microphone speaker and battery are not part of the modem The SIM card is mounted in the modem accessible by the user under a lid without any tool...

Страница 6: ...supplying and controlling DC power to the modem The supply voltage VCC required by the modem is in the range 5V 36V DC Application of the supply voltage does not switch the modem on To do so an addit...

Страница 7: ...line used to switch off VIH 5V VIL 0 5V Power off 1s t 2s 4 TO_IN Input 5 36V Positive edge triggered signal used to switch on the modem VIH 5V VIL 0 5V Power on t 1s 5 DIG_OUT or not connected Outpu...

Страница 8: ...or so you can connect a handset or microphone speaker system here available for the GT864 QUAD only GT864 PY with GPIO The programmable GT864 PY provides digital inputs on that connector so you can us...

Страница 9: ...tivity of a headset or any other audio equipment using the analogue microphone and loudspeaker interface of GT864 QUAD Terminal The table below describes the signals on the USB connector GT864 QUAD Pi...

Страница 10: ...vel 12 30V ESD protected under full control of embedded application GT864 PY Pin Layout for Mini USB connector GT864 PY GPIO GT864 PY PIN Mini USB Mini USB PIN GPIO 11 D1 IN1 1 GPIO 12 G4 IN2 2 GPIO 1...

Страница 11: ...max 10 1 VSWR recommended 2 1 2 4 SIM card reader The GT864 QUAD PY Terminal is fitted with a SIM card reader designed for 3V SIM cards It is the flip up type which is lockable in the horizontal posi...

Страница 12: ...dition the DCE for data transmission The default level is high by internal pull up The exact behaviour of RTS is defined by an AT command Software or Hardware control can be selected Hardware flow is...

Страница 13: ...The modem can be configured to start up at the time power is applied by permanently tying power connector signals TO_IN pin 4 and VCC pin 1 together In this case DTR must be used to switch the modem o...

Страница 14: ...R permanently to low 0 8V HR_IN to high level for 1s t 2s A delay of up to 10s is experienced as the modem logs off the network 3 3 Operating states LEDs 3 3 1 Power up LED green LED in the middle The...

Страница 15: ...ed for signalling any useful status of the external application such as error indication status of communication GPRS SMS CSD etc status of GSM network to simulate GSM LED quality of service 4 Power c...

Страница 16: ...You are responsible for observing your country s safety standards and where applicable the relevant wiring rules 4 2 General precautions The GT864 QUAD PY Terminal as a stand alone item is designed f...

Страница 17: ...e consider the risk of lightning Follow the instructions provided by the antenna manufacturer Never connect more than one modem to a single antenna The modem can be damaged by radio frequency energy f...

Страница 18: ...h can be the result of a disturbance from another source for example an electronic device in the immediate vicinity More information about possible communication disturbances can be found in section 5...

Страница 19: ...y attach the GT864 QUAD PY Terminal modem to the host application using two 3mm diameter pan head screws 5 3 Antenna 5 3 1 General The antenna is the component in your system that maintains the radio...

Страница 20: ...al areas and light industry can withstand a minimum of 3V m 5 3 4 The antenna cable Use 50 impedance low loss cable and high quality 50 impedance connectors frequency range up to 2GHz to avoid RF loss...

Страница 21: ...e with communication and may cause a delay or at worst a disruption 5 4 CEP Certified Accessories Product Description Power supply 230V AC 12 VPC 6pin RJ11 connector Power cable 6pin RJ11 connector wi...

Страница 22: ...p 850 900 MHz 106 dBm typ 1800 1900 MHz Overall dimensions excluding connectors 77 x 67 x 26mm Weight ca 90g RoHS compliant Temperature range o 30 C to 75 C Operational o 40 C to 85 C Storage temperat...

Страница 23: ...Asynchronous non transparent circuit switched Data CSD up to 9 6 kbps V 110 GPRS Data GPRS Class 10 Mobile station class B GPRS Coding Scheme 1 4 Fax Fax Group 3 class 1 GSM supplementary Call forwar...

Страница 24: ...internally implementing the application code directly in the Python language Memory 3MB of NV memory for the user scripts and 1 2MB RAM for the Python engine usage Over the Air Application SW update T...

Страница 25: ...y EFR Enhanced Full Rate EMC Electro Magnetic Compatibility ETSI European Telecommunication Standards Institute FR Full Rate GPRS General Packet Radio Service GSM Global System for Mobile Communicatio...

Страница 26: ..._______________________________________________ __________________________________________________________________________________________ Page 26 of 28 8 Mark of Conformity The GT864 QUAD PY Terminal...

Страница 27: ...n 1 2 _________________________________________________________________________________ __________________________________________________________________________________________ Page 27 of 28 8 2 RoH...

Страница 28: ...contact customer support please use the contact details below Customer Support CEP AG Raiffeisenallee 12b 82041 Oberhaching Germany E mail support cepag de or Tel 49 89 450 292 11 Information about CE...

Отзывы: