MAINTENANCE
SENSEI 86038580 02/08/07
4-2
Only qualified
maintenance personnel
are to perform the
following repairs
.
VACUUM MOTOR REPLACEMENT
1. Turn off all switches and unplug machine.
2. Remove
recovery
tank.
3. Locate the vacuum motor wires and disconnect
at the connector.
4. Remove the vacuum motor.
5. Reverse process to install vacuum motor.
SOLUTION PUMP REPLACEMENT
1. Turn off all switches and unplug the machine.
2. Remove
recovery
tank.
3. Remove solution hoses from fittings in pump.
4. Remove the screws that fasten the pump to the
frame.
5. Reverse process to install pump.
Vacuum Motor Carbon Brushes Replacement (Windsor)
WARNING:
The green
ground wire must be
attached for safe operation.
See wiring diagram.
End Cap
Carbon
Brushes
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a
qualified service center.
Important:
These brushes wear quicker as the length shortens due to
increased heat. Spring inside brush housing will damage
motor if brushes are allowed to wear away completely.
Periodically check the length of the carbon brushes. Replace
both carbon brushes when either is less than 3/8" (9.5mm)
long.
3
8
[9.5mm]
Important:
These brushes wear quicker as the length shortens due to
increased heat. Spring inside brush housing will damage
motor if brushes are allowed to wear away completely.
Periodically check the length of the carbon brushes. Replace
both carbon brushes when either is less than 3/8" (9.5mm)
long.
3/8 (9.5mm)
Vacuum Motor Carbon Brushes Replacement (Ametek)
Note:
When replacing carbon brushes loosen wire terminal
BEFORE
removing screws on bracket.
Note:
Place
stop in
groove.
Wire
Terminal
WARNING:
The green
ground wire must be
attached for safe operation.
See wiring diagram.
End Cap
Carbon
Brushes
Wire Terminal
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a
qualified service center.
Содержание Sensei 406-131MO
Страница 10: ...CONTROLS SENSEI 86038580 02 08 07 3 2 ON OFF OFF ON VAC PUMP 1 Vacuum Switch 2 Pump Switch 1 2 ...
Страница 16: ...PUMP GROUP 50 PSI SENSEI 86038580 09 20 10 5 1 2 3 9 1 2 3 4 5 6 7 8 ...
Страница 18: ...PUMP GROUP 100 PSI SENSEI 86038580 02 08 07 5 3 8 2 3 6 2 3 1 7 5A 5B ...
Страница 24: ...VACUUM MOTOR GROUP SENSEI 86038580 02 08 07 5 9 3 1 2 4 5 ...
Страница 26: ...WIRING DIAGRAM SENSEI 86038580 02 08 07 5 11 ...