MACHINE OPERATION 

 SENSEI 86038580  02/08/07 

3-3 

 
GENERAL INFORMATION 
As the carpet is being cleaned, check to see 
if there is  foam building up in the recovery 
bucket.

  Add a little defoaming compound to the 

recovery tank but never to the solution tank. 
 

For infrequent use or long periods of 
storage

, flush the system with a neutralizing 

solution of 1 quart white vinegar mixed with 2 
gallons hot water.

  

Flush the system with clean 

hot water after neutralizing. 
 

For hose fitting lubrication

, use a light silicone 

lubricant which will not damage o-rings. 
 

PROTECT THIS MACHINE FROM 
FREEZING. 

 
PRE-RUN INSPECTION 

1.  Check all fittings and connectors for proper 

assembly. 

 
2.  Check all hoses for leaks.  Repair or replace 

any damaged hoses. 

 
3.  Check power cord(s) for any damage.  If 

damaged, replace. 

 

EQUIPMENT SET-UP 

1.  Plug power cord from machine into properly 

grounded wall outlet. 

 
2.  Turn vacuum motor switch on and off to 

make sure there is electrical power at 
machine. 

 
3.  Connect vac hose to machine.  Slide the 

swivel cuff over the outlet on the tank. 

 
4.  Connect the hose to your machine and 

wand.  Pull back the knurled collar on the 
quick disconnect coupler (located on the 
solution tank) and push into the connection.   

 

To avoid leaks, check to be sure that a 
positive connection was made. 

 
5.  Using a clean container, fill the solution tank 

with clean hot water.  Mix in a non-foaming 
cleaning concentrate for use in hot water 
extraction machines, following the 
manufacture’s instructions printed on 
container. 

 
 

 
NOTE
:

  When using a powder cleaner, pre-mix 

with hot water in a clean container before adding 
to the solution tank. 
 
6.  Turn pump and vacuum switch(s) to the on 

position. 

 
7. Start 

cleaning. 

 

EMPTYING AND CLEANING 
 
 
 
Always use defoamer if foaming occurs. 
Foam will suspend large particles that may 
damage vacuum(s) as well as allow liquid 
into the vacuum motor(s) without activating 
the float shutoff. 

 
1.  Before proceeding, make certain that the 

nozzle is functioning properly. 

 

a.  To check, hold the wand about one foot 

above the surface to be cleaned and 
open the wand valve.  A full spray should 
be observed from the nozzle. 

 
b.  If the nozzle is not showing a full spray 

pattern, adjust nozzle for proper pattern, 
clean, or replace nozzle. 

 

2.  Normally, chemical is applied on the push 

stroke of the wand when cleaning.  
Vacuuming is done on the pull stroke.  For 
heavily soiled carpets the wand may be used 
in a scrubbing manner, applying chemical in 
both the push and pull stroke. 

 
3.  When cleaning, keep the working opening  

(wand mouth) flat on the surface being 
cleaned.  Keep the wand moving when the 
valve is open. 

 
4.  The shutoff float inside the vacuum tank will 

impede the vacuum flow when the vacuum 
tank is full. When this occurs, empty the 
vacuum tank by opening the dump valve and 
dispose of the waste in a proper manner.   

 
5.  Once the vacuum tank has been emptied, 

you may once again proceed with cleaning 

 

 
 

Содержание Sensei 406-131MO

Страница 1: ...MODELS 406 135MO 10070260 406 131MO 10070240 Operating Instructions 86038580 05 16 11 PRV NO 98832 R PORTABLE EXTRACTOR Read these instructions before using the machine ...

Страница 2: ...his appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank Warranty Registration Thank you for purchasing a C400 product Warranty registration is quick and easy Your registration will allow us to serve you better over the lifetime of the product To register your product go to www century400 com support warranty register php For customer as...

Страница 3: ...Operation 3 3 Pre Run Machine Inspection 3 3 Equipment Set up 3 3 Emptying Cleaning Tanks 3 3 MAINTENANCE Daily Maintenance 4 1 Periodic Maintenance 4 1 Monthly Maintenance 4 1 Semi annually 4 1 Lubrication 4 1 Storage 4 1 Vacuum Motor Replacement 4 2 Solution Pump Replacement 4 2 Pump Replacement Kit 4 3 Machine Troubleshooting 4 4 GROUP PARTS LIST Pump Group 50 psi 5 1 Pump Group 100 psi 5 3 Rec...

Страница 4: ...function of the machine The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition They are listed in this general order Maintenance Lubrication Vacuum Motor Replacement Solution Pump Replacement Troubleshooting The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of...

Страница 5: ...uthorized service center Do not pull or carry machine by electrical cord use as a handle close a door on cord or pull cord around sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord To unplug grasp the electrical plug not the electrical cord Do not handle the electrical plug or machine with wet hands Do not operate the ma...

Страница 6: ...must be followed for safe operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equipment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take ...

Страница 7: ... LOCATION SENSEI 86038580 02 08 07 2 3 NOTE These drawings indicate the location of safety labels on the machine If at any time the labels become illegible promptly replace them LABEL WARNING 86242230 PRV NO 500009 ...

Страница 8: ...let that is properly installed and grounded in accordance with all local codes and ordinances This appliance is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug in Fig A A temporary adaptor that looks like the adaptor in Fig C may be used to connect this plug to a 2 pole receptacle as shown in Fig B if a properly grounded outlet is not available The temporary ...

Страница 9: ...ution Pump 50 psi 100 psi Solution Capacity 7 gal 26 L Recovery Capacity 6 gal 22 L Weight Empty 50 lbs 110 kg Weight Full Solution 105 lbs 230 kg Height 35 inches 88 90 cm Height Handle Folded Down 28 5 inches 72 39 cm Length 25 inches 63 50 cm Width 15 5 inches 39 37 cm Power Cord 22 feet 6 71 m HEIGHT HEIGHT WIDTH LENGTH ...

Страница 10: ...CONTROLS SENSEI 86038580 02 08 07 3 2 ON OFF OFF ON VAC PUMP 1 Vacuum Switch 2 Pump Switch 1 2 ...

Страница 11: ...t water Mix in a non foaming cleaning concentrate for use in hot water extraction machines following the manufacture s instructions printed on container NOTE When using a powder cleaner pre mix with hot water in a clean container before adding to the solution tank 6 Turn pump and vacuum switch s to the on position 7 Start cleaning EMPTYING AND CLEANING Always use defoamer if foaming occurs Foam wi...

Страница 12: ...severe burns and serious injury PERIODIC MAINTENANCE 1 Twice a month flush a white vinegar solution One quart vinegar to two gallons of water or anti browning solution mixed as directed through the extractor turning pump switch on off several times flush with clean water This will prevent build up of alkaline residue in the system 2 Check hoses for wear blockages or damage Frayed or cracked hoses ...

Страница 13: ...e center Important These brushes wear quicker as the length shortens due to increased heat Spring inside brush housing will damage motor if brushes are allowed to wear away completely Periodically check the length of the carbon brushes Replace both carbon brushes when either is less than 3 8 9 5mm long 3 8 9 5mm Important These brushes wear quicker as the length shortens due to increased heat Spri...

Страница 14: ...9206 Pump Head Replacement 86251040 PRV NO 65187 PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI 86201430 PRV NO 250 64A PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI 86251110 PRV N0 65219 DIAPHRAM 86235120 PRV NO 29219 86191390 PRV NO 65240 PUMP HEAD 86258860 PRV NO 84166 VALVE ASM 86247360 PRV NO 53245 MOTOR ...

Страница 15: ...g wand to relieve air Pump runs no solution Internal or external solution line damaged and leaking Replace Internal pump components wearing out Replace see pump kit components pg 4 3 Pump runs loss of pressure Check valves in pump head for particles or cuts in seals Take piston from BPR and lubricate with Superlube If problem still exists change BPR kit Unit not plugged in Connect unit to 3 prong ...

Страница 16: ...PUMP GROUP 50 PSI SENSEI 86038580 09 20 10 5 1 2 3 9 1 2 3 4 5 6 7 8 ...

Страница 17: ... RBR X 11 2 86233150 20042 2 CLAMP 3 8 HOSE D SLOT 3 86001550 40043 2 HOSEBARB 3 8 MPT X 3 8 90D 4 86201410 250 63 1 SHURFLO 50PSI PUMP 5 86199960 110 22 4 GROMMET 6 GAL PORT 6 86010630 87013 2 WASHER 1 4 ID X 5 8 OD SS 7 86273830 70020 2 SCR 1 4 20 X 1 2 HHCS SS NP 8 86281250 39311 1 HOSE 3 8ID 300PSI 70F X 14 9 86312660 1 BASE PUMP MOTOR ...

Страница 18: ...PUMP GROUP 100 PSI SENSEI 86038580 02 08 07 5 3 8 2 3 6 2 3 1 7 5A 5B ...

Страница 19: ... 11 2 86233150 20042 2 CLAMP 3 8 HOSE D SLOT 3 86001550 40043 2 HOSEBARB 3 8 MPT X 3 8 90D 4 OPEN 5A 86201430 250 64A 1 SHURFLO 100 PSI PUMP DEMAND 5B 86251110 65219 1 PUMP 115V 100PSI BYPASS W SW FLOJET 6 86010630 87013 2 WASHER 1 4 ID X 5 8 OD SS 7 86273780 70015 2 SCR 1 4 20 X 3 4 HHCS SS NP 8 86281250 39311 1 HOSE 3 8ID SGLBRD RBR X 14 ...

Страница 20: ...RECOVERY TANK GROUP SENSEI 86038580 02 08 07 5 5 3 4 5 6 9 10 11 12 14 16 17 18 20 21 22 23 24 13 26 15 1 27 7 8 19 2 25 28 15 ...

Страница 21: ...86200710 140 03 1 LATCH DRAW PULL 6 GAL 12 86006490 70013 2 SCR 8 32 X PPHMS SS 13 86161460 15 808123 1 DUMP VALVE 2 14 86161470 11 800444 1 ELBOW 2 45D PVC SCH40 15 86237770 35256 2 GASKET DUMP VALVE 16 86033460 75338 1 TANK RECOVERY LT GRY 17 86199320 110 14A 3 CAP PLUG 1 18 86005680 57047 2 NUT 20 HEX NYLOCK 19 86006850 70393 2 SET SCR 1 4 20 X 1 25L 20 86010740 87090 2 WASHER 1 4 ID X 3 4 OD P...

Страница 22: ...ANK GROUP SENSEI 86038580 02 08 07 5 7 PARTS INSIDE TANK CONNECT TO PUMP ASM 4 5 7 8 6 6 1 2 9 10 41 6 11 12 6 14 13 15 18 19 22 20 21 17 16 23 24 28 29 30 18 31 32 33 34 35 38 37 39 39 40 36 3 26 27 43 42 25 23 ...

Страница 23: ... 5 8 OD SS 19 86273780 70015 1 SCR 1 4 20 X 3 4 HHCS SS NP 20 86199540 060 04A 1 CORD ASM 14 3 SJT X 25 BLK 21 86202160 320 05 1 VELCRO STRAP 22 86256180 73195 1 STRAIN RELIEF 3 4 NPT 23 86010650 87018 4 WASHER 10 X 9 16 OD 24 86273930 70051 2 SCR 8 32 X 1 2 PPHMS NP 25 86006520 70052 2 SCR 8 32 X 3 8 PPHMS SS 26 86270920 57049 3 NUT 6 32 HEX NYLOCK SS 27 86200030 41394 1 HINGE ACCESS PLATE 28 862...

Страница 24: ...VACUUM MOTOR GROUP SENSEI 86038580 02 08 07 5 9 3 1 2 4 5 ...

Страница 25: ... 3 VAC SPACER 3 1 8 2 86010630 87013 3 WASHER 1 4 ID X 5 8 OD SS 3 86273970 70062 3 SCR 1 4 20 X 4 HHCS GR5 PLTD 4 86258420 53130 1 VAC MOTOR 120V 5 7 3ST W O TB 86135320 140687 BRUSH SET 120V VAC WINDSOR SERVICE ONLY 86135300 140676 BRUSH SET 120V 3ST VAC AMETEK SERVICE ONLY 5 86003720 35011 1 GASKET 3 8T 5 7 VAC FAN SEAL ...

Страница 26: ...WIRING DIAGRAM SENSEI 86038580 02 08 07 5 11 ...

Страница 27: ...620 260 64A ACCESS COVER CLEAR 6 W RIM 86161470 11 800444 ELBOW 1 5 FS X FS 45D PVC 86256960 72142 SWITCH SPST 15A EURO ROCKER 86202160 320 05 VELCRO STRAPS 86003720 35011 GASKET 3 8T 5 7 VAC FAN SEAL 86200510 140 12 KNOB 1 4 20 X 3 4 S S CUPPOINT 86135320 140687 BRUSH SET 120V VAC WINDSOR 86135300 140676 BRUSH SET 120V 3ST VAC AMETEK ...