EZY-System Manual 

Page 4

1.2 SYSTEM DEFINITIONS, SYMBOLS, WARNING, CAUTIONS AND NOTES 

 

Please read this section thoroughly before operating your Centurion System. Included below are 
definitions of terminology and symbols used in this manual and/or used on equipment markings, 
operational warnings, cautions and notes for the safe operation of the Centurion EZY System. 

 
 
DEFINITIONS 

 
WARNING 

 

Specific Information provided to the user to advise of situations where the misuse or 
unlabelled use of the device could present potential harm to the user or patient and/or 
could result in irreparable damage to the device or property.  Also found on equipment to 
alert reader to consult accompanying documents prior to operation.

 

 
CAUTION 

 

Specific information provided to the user to prevent misuse of the device that may cause 
it to malfunction.

 

 
NOTES 

 

General information provided to the user to further explain or clarify the proper operation 
of the device. 

 

APPLIED PART 

 

 

“Applied Part” is the term used to refer to the applicator that is used to provide the actual 
session to the patient. (“Lightweight Coil”) 

   

WARNINGS - GENERAL

 

 

Do not splash or expose electric parts of the system to water or moisture. Doing so 
may permanently damage it and/or result in significant personal injury and 
property damage. 

 
NOTE: 

Pulsating Magnetic Fields are used as an aid in the management of chronic pain and  

               musculoskeletal conditions. 

 
 
1.3 CONTRAINDICATIONS 
 

WARNING 

- Magnetic fields are produced when the modality is operational and  

                              may interfere with Pacemakers and Electronic Stimulators. 

WARNING 

- During the last trimester of Pregnancy, the therapy should not be used. 

 

NOTE: Although the system is very simple and safe to use, it is always wise to 
consult with a physician about any new indication 
 
 

Содержание EZY System

Страница 1: ...October 2016 Operation Manual for use as an aid in the management of musculoskeletal disorders Pulsed Magnetic Field Therapy EZY System Centurion...

Страница 2: ...2 Installation Instructions 2 1 System Contents 5 2 2 System Assembly 5 2 2 1 Connection of Power and Applied Part 5 2 2 2 Positioning of the Coil 7 3 Operating Instructions 3 1 The EZY System Contro...

Страница 3: ...17 6 Troubleshooting 6 1 General Operation Checkup 18 6 2 General Troubleshooting 19 7 Technical Specifications 7 1 Regulatory Compliance 20 7 2 Equipment Classifications 20 7 3 Electrical Specificat...

Страница 4: ...a conductor a magnetic field will be set up in that conductor that is perpendicular to the conductor and if combined with other conductors as is found in a coil structure these fields are additive By...

Страница 5: ...nt misuse of the device that may cause it to malfunction NOTES General information provided to the user to further explain or clarify the proper operation of the device APPLIED PART Applied Part is th...

Страница 6: ...in your system 1 EZY System Handheld Controller 1 EZY System Lightweight Coil 1 Applied Part Cable 1 Power Cord 1 Power Adapter Assembly 1 Operating Manual 1 Test Magnet 2 2 SYSTEM ASSEMBLY The Centu...

Страница 7: ...G Do not remove the ground pin from the power cord or bend it over or use an extension cord that will allow the cord not to be connected to ground Failure to maintain a proper ground while operating t...

Страница 8: ...s you may find alternative positions that maximize your comfort during treatment sessions While the EZY System is lightweight and can easily be positioned as and where needed the elderly and infirm ma...

Страница 9: ...ure 6 Thighs Figure 7 Thighs Figure 8 Lower Back Figure 9 Abdomen Figure 10 Shoulders You may find that some coil positions are more comfortable in a lying pose Experiment with the EZY System on a cha...

Страница 10: ...ction switches that are conveniently located on the front of the unit Session time is selectable in ten minute increments ranging from 20 minutes to 60 minutes When FREQ frequency and TIME selections...

Страница 11: ...2016 EZY System Manual Page 10 Figure 12 Turn Controller ON Figure 13 Select Frequency Figure 14 Switch to Time Selection Figure 15 Select Treatment Time Figure 16 Start Treatment Figure 17 Stop Trea...

Страница 12: ...selected ie the higher the frequency the quicker the light will pulse 6 You may stop or pause the treatment by pushing the START STOP button at any time see Figure 17 New frequency and time settings...

Страница 13: ...f cells which function electrically See Figure 18 Electric potential has a strong relationship to cellular viability Our cells have a basic or rest potential that is necessary for normal cellular meta...

Страница 14: ...important setting The frequency settings of the Centurion EZY System range from 2 to 30 Hz As seen in Figure 31 normal Earth magnetic energy varies between 8 and 10 Hz In the Centurion EZY System the...

Страница 15: ...ere there is still discomfort in the area of concern it is recommended that treatment remain at 2 Hz Acute conditions may subside quicker B STIMULATION After completion of the first priority stimulati...

Страница 16: ...original indication a previous loss of circulation had occurred The Reactive Phase can easily be recognized by a dramatic increase in discomfort or swelling in the area If this happens there is no ne...

Страница 17: ...erviced before using CAUTION Inspect all cables and applied part daily for any signs of deterioration or damage Do not use damaged cables as they may present an electrical shock hazard If damage is ob...

Страница 18: ...y may arrange to have the equipment picked up by their own shipping service or pay the additional cost above normal shipping costs for overnight or the best service available When sending in equipment...

Страница 19: ...ed on the time spent to evaluate the service problem All out of Warranty repairs will be warranted for 30 Days from the date of shipment to the owner END OF LIFE INSTRUCTION Centurion Systems are desi...

Страница 20: ...r off push the TIME FREQ SELECT button so that the TIME light illuminates Test the availability of time selections cycling through the minutes 20 30 40 50 and 60 by pressing the UP and DOWN buttons Le...

Страница 21: ...13485 2003 ISO 14971 2009 7 2 EQUIPMENT CLASSIFICATIONS Class 3 Electrical Equipment IEC 60601 Degree of protection against Electrical shock Type BF Applied Part Mode of Operation Continuous 7 3 ELEC...

Страница 22: ...nd and short enough that you are not bound to a long term agreement At the end of the three month rental period there are a number of programs available to help you acquire the Centurion System on a l...

Страница 23: ...nada L4W 3A4 Phone 905 238 4860 Fax 905 238 9140 Toll Free 1 800 387 8326 WORLDWIDE Toll Free 1 800 387 8326 E Mail info centurion systems com Website www centurion systems com Centurion MAGNETIC FIEL...

Отзывы: