background image

Mounting the origin marker

1.

Close the gate completely.

2.

Mount the origin marker to 
the rack a minimum of 
500mm from the origin 
sensor.

3.

For steel rack mount the 
origin marker onto the rack 
using the bracket provided.

4.

Weld the bracket to the 
rack.

5.

Bolt the origin marker onto 
the bracket using the 
fasteners provided.

6.

With RAZ rack the origin 
marker mounts directly on 
top of the rack without a 
bracket.

7.

Drill mounting holes 
directly into the rack and 
bolt into position.

8.

File away the front lip of 
the rack if you need to 
move the origin marker 
closer to the operator as 
the gate slides past.

9.

With nylon angle rack it is 
necessary to use the 
bracket provided.

10. It is preferable to use self 

tapping fasteners to secure 
the bracket into the side of 
the nylon rack as shown.

11. Make a small tack weld to 

secure the back of the 
bracket onto the angle iron 
section of the rack.

12. Bolt the origin marker onto 

the bracket using the 
fasteners provided.

Steel rack

RAZ rack

Nylon angle rack

Содержание D5-EVO REPAIR

Страница 1: ......

Страница 2: ... starting 30kgf Operator push force rated 17kgf Gate mass maximum 500kg Gate length maximum 100m Maximum numbers of operations per day 150 Please do not proceed with the installation until you have read and fully understand the Safety Instructions included in your product packaging The Safety Instructions are also available on www centsys co za and may also be obtained by contacting Centurion Syst...

Страница 3: ...2 Courtesy light fuse 3A F B 3 Gate mounted origin marker 4 Origin marker bracket 5 Origin sensor 6 Side covers 7 8 9 1 x 12v 7 2Ah battery 10 SM2A charger 11 Manual release access door Foundation plate Motor fuse 30A ATO ...

Страница 4: ...ed to have sufficient clearance between moving parts when opening and closing to reduce the risk of personal injury and entrapment Pushbuttons or key switches when required can be positioned so that the gate is in line of sight of the operator Install the gate operator only if Guide rollers must ensure that the gate is held vertically though the entire length of the gate travel For improved safety...

Страница 5: ...battery so that you can gain access to the coloured filler plug 3 Remove the coloured oil filler plug by levering it out with a screwdriver 4 Empty the contents of the oil bottle into the gearbox 80ml 5 Refit the coloured oil filler cap Oil specifications Centurion product code OIL80ML0X0 H Castrol SAF XO 75w 90 Synthetic Final Drive Lubricant Make H h to ensure gate will not jump over end stop as...

Страница 6: ...NE SWA size according to power requirements n1 number of cores required by intercom n2 number of cores required by intercom Possibly increase cable thickness if pillar lights are installed Type of cable must adhere to municipal bylaws but typically SWA steel wire armoured cable is recommended The armouring provides excellent screening which gives better protection against lightning earth one end o...

Страница 7: ...lly 3 If the gearbox must be left in manual mode for an extended period of time for whatever reason it is recommended that the access door is locked This secures the cover and prevents access to the inside of the unit which contains high voltages It also prevents theft of any components and provides full protection from the elements 1 Rotate thumbwheel anti clockwise until thumbwheel feels loose i...

Страница 8: ...rollers and anti lift brackets are correctly fitted The gate mass starting and rated pull force limitations are not exceeded The D5 Evo is positioned correctly and does not protrude into the driveway Locate operator position 1 To ensure operator does not protrude into driveway install base plate at least flush with the driveway entrance 2 Determine a suitable position and vertical height for the o...

Страница 9: ... a template for marking the rawl bolt holes Assemble foundation plate without anchor brackets before bolting down onto plinth Ensure that the M10 gearbox mounting bolts are properly tightened Option 2 Bolting foundation plate onto an existing concrete plinth Option 1 New concrete foundation Assemble foundation plate with anchor brackets as shown in the illustration Ensure that the M10 gearbox moun...

Страница 10: ...how the cables route up onto the control card 6 Check that the operator is level 7 Secure the gearbox in place fitting the following in sequence first a nut and then a washer onto each gearbox mounting then the gearbox and then a washer followed by a spring washer and finally a nut onto each gearbox mounting 8 Do not mount gearbox flat down onto mounting plate Adjust the height of the mounting nut...

Страница 11: ...gle brackets provided 2 Brackets must be spaced no more than 300mm apart 3 When joining different lengths of steel rack a simple way of ensuring correct pitch spacing is to clamp a small off cut between the two pieces RAZ rack 1 Use at least three TEK screws per half metre section of rack Fit additional fixing screw through the horizontal slots to secure the rack to the gate directly above the pin...

Страница 12: ...ut a bracket 7 Drill mounting holes directly into the rack and bolt into position 8 File away the front lip of the rack if you need to move the origin marker closer to the operator as the gate slides past 9 With nylon angle rack it is necessary to use the bracket provided 10 It is preferable to use self tapping fasteners to secure the bracket into the side of the nylon rack as shown 11 Make a smal...

Страница 13: ...cified distance is achieved It is possible to make the distance between the marker and the sensor much greater than 500mm However if using the pedestrian opening facility although the position of the marker will not affect the width of the pedestrian opening it is preferable to have the marker mounted inside of the pedestrian opening point Take care with the orientation of the arrow on the origin ...

Страница 14: ......

Отзывы: