Diagnostic LEDs
The
D2 Turbo
controller has a series of diagnostic LEDs which indicate the state of the
inputs. Normally-open inputs are indicated by a RED LED, and normally-closed inputs by
a GREEN LED. An illuminated RED LED indicates that the signal is present (e.g. intercom
button pressed), while an illuminated GREEN LED indicates that the signal is absent (e.g.
infrared Safety Beam not broken).
Safety OPN:
Green
On when the opening beam is not activated
Safety CLS:
Green
On when the closing beam is not activated
LCK/STP:
Green
On when the LCK/STP input is not activated
Status:
Red
This LED indicates the state of the gate as per
the table below
TRG:
Green
On when a trigger signal is present
PED:
Green
On when the pedestrian signal is present
AUX:
Green
On when an auxiliary signal is present
FIGURE 137.
page 79
24. Diagnostics
Buzzer feedback
A warning buzzer will sound (where applicable) as per the table below:
Inhibitor
name
Battery-low
Beams broken
(any)
Safety beams
failure
Mains failure
Multiple collisions
Holiday Lockout
Number
of beeps
3 beeps every two
seconds for 30 seconds
Periodic until condition
is cleared by user
1 beep periodically
for 30 seconds
3 beeps each time
the gate is triggered
2 beeps every
two seconds for
30 seconds
3 beeps periodically
for 30 seconds
Priority
1
2
5
6
3
4
Fault
type
User
User
Collision
User
Power
system fault
Power
system fault
Gate
continues
to operate
Yes
No
No
No
No
User can
correct
error
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Gate will close fully and then shutdown for two minutes
*
*