page 46
Menu 8 - Courtesy (pillar) light
This feature is associated with the
light
connections on the controller. Refer to
Section 16 of the manual for details on how to connect a pillar or security light to
the controller.
The pillar light circuit has multiple functions:
It operates as a courtesy light and switches on for a selectable time period
every time the gate is activated
The courtesy light can also be turned on for the same time period by
momentarily connecting the Aux terminal to the Com terminal via a pushbutton
The courtesy light can also be turned on permanently by connecting the Aux
terminal to the Com terminal via a pushbutton, for three seconds. A short pulse
thereafter will switch the lights off. The status LED will flash once every two
seconds to indicate that the courtesy light is on permanently. The
abovementioned facility can also be achieved via a remote learned to the
system and mapped to the courtesy light function from within the remotes
menu
The gate will not open when using the
Aux
trigger input.
When the Ped input is triggered, the courtesy light flashes for an adjustable (1 to
255 seconds) pre-flash time, before the pedestrian gate opens
The courtesy light can also be controlled via the
Auto activation
function, or the
light time-bar function as described in the ChronoGuard (Time-periods) menu -
Menu 9
Courtesy light time
The time that the courtesy light will remain activated can be set from four
seconds to ten hours in one second increments.
Light profile
The courtesy light can be selected to operate according to one of the following:
Courtesy light
as explained earlier
Pre-flashing mode
If pre-flashing Mode A, B or C is selected, the behaviour of the courtesy light
will be as follows:
Mode A
will turn on the courtesy light only while the gate is moving
Mode B
will flash the courtesy light during the pre-opening and pre-closing
delays, as well as while the gate is moving
Mode C
will turn on the courtesy light during the pre-opening and pre-
closing delays, as well as while the gate is moving
In these pre-flashing modes, the timed courtesy light functionality is not
available
Menu 9 - ChronoGuard (Time periods)
ChronoGuard™
(patent pending) is a powerful feature which has been added to
the new generation CENTSYS controllers. An integral
Real Time Clock
(RTC) is
used to provide time-based functionality, including the automatic activation or
time-barring of specific controller inputs, and the time-barring of specified