SPECIFICATIONS
D3
D5
Maximum number of operations per day (Average)
Mains Present:
Standby;
Maximum number of continuous operations per hour
Mains Present:
Temperature range
-10° to +50°C
-10° to +50°C
Corrosion protection (baseplate)
Galvanized
Galvanized
Housing protection
IP55
IP55
Control card *
CP80
CP80
Mass of unit (packed) including 7.5Ah Battery
12kg
13.5kg
Collision sensitivity
Electronic, adjustable
Electronic, adjustable
End of travel control
Sealed optical counter
with origin switch
Sealed optical counter
with origin switch
Typical time to open/close a 4m gate
(With gate pull force <5kg)
16 seconds
13 seconds
With 40Ah Battery (One day)
N/A
150
With 7Ah Battery (Half day)
20
61
Battery driven (1A charge, 7Ah battery)
Battery driven (2A charger, 7Ah battery
Power pack (10A power pack, no battery)
10
30
20
10
N/A
N/A
Battery driven (1A charger, 7Ah battery)
Battery driven (2A charger, 7Ah battery)
Power pack (10A power pack, no battery)
20
N/A
N/A
50
150
100
Maximum gate mass
300kg
500kg
Rated pull force
12kgF
20kgF
Starting pull force
20kgF
30kgF
Output shaft rotational speed
73rpm
91rpm
DC Current draw (Max)
15A
15A
AC Current draw @ 220V
60mA
170mA
Motor Voltage
12V DC
12V DC
Power supply voltage
(Depending on power supply used)
220-240V AC ± 10% 50Hz
110V AC ± 10% 50Hz
19V AC ± 10% 50Hz
220-240V AC ± 10% 50Hz
110V AC ± 10% 50Hz
19V AC ± 10% 50Hz
* D3 and D5 have different micro-controller versions
Rated Gate Speed (With gate pull force <5kg)
16m/min
20m/min
11m
11m
Maximum gate length
Page 23
CENTSYS D3 and D5
Specifications
Specifications
Содержание A10
Страница 1: ...D3 D5 and A10 User guide TM TM TM DOMESTIC AND INDUSTRIAL SLIDING GATE OPERATORS ...
Страница 29: ...Notes Notes ...
Страница 30: ...Notes Notes ...
Страница 31: ...Notes Notes ...
Страница 32: ...www centsys com au 0 07 B 0031 D3 D5 and A10 User guide 10Jul2012 ...