Centrometal CentroPelet ZVB 16 Скачать руководство пользователя страница 23

GB

Following  the  cleaning  of  the  upper  compartment  of 
the  exchange  section,  store  the  upper  closure  cover.  
This cover must be closed, as well as with normal screws, 
with webbing in ceramic fiber rope to ensure the 
watertight closure of the 

boiler

.

This  general  cleaning  should  be  carried  out  at  the  end 
of  the  season  in  order  to  facilitate  the  general  removal 
of  all  residues  of  combustion,  without  waiting  too  long, 
because  with  time  and  humidity  these  residues  can 
become compacted. 
Check the seal of the ceramic fiber gaskets on the door of 
the 

boiler

.

Then clean the flue system especially near the fittings to 
“T” and any horizontal sections. 

For your safety, the frequency of cleaning 
the  smoke  discharge  system  must 
be determined on the basis of how 
the 

boiler

 is used. 

In case of failure or inadequate cleaning of the heater 
may have function problems such as:

• poor combustion
• blackening of the glass
• clogging of grate with accumulation of ash and pellets
• ash deposit and excessive deposits on the heat ex-
changer resulting in poor performance.

The check of electromechanical components must be 
performed only by qualified personnel with technical 
knowledge of electricity and combustion.

Surface cleaning

The 

boiler

  is  a  product  by  heating,  presents  the 

external surfaces particularly hot.
For  this  reason,  we  recommend  extreme  caution  when 
operating in particular:
• Do  not  touch  the 

boiler

  body  and  the  various

components, do not approach the door, it could cause burns;
• Do not touch the exhaust fumes;
• Do not perform any type of cleaning;
• Do not dump the ashes;
• Do not open the ash tray;
• Be careful that children do not come close.

All cleaning of all parts must be carried out with the 

boiler

 

completely cold and the plug disconnected.
To clean the surfaces, use a rag dampened with water or 
with water and a neutral detergent.

These operations must be performed by a 
qualified technician, or the user who will 
take responsibility in the event of damage 

during maintenance.
Perform  this  maintenance  heater  cold  and  in  the 
absence of electricity. If such maintenance is 
performed by an authorized service center is the 
responsibility of the customer.

The transaction can be completed with a screwdriver by 
removing  the  wall  of  the 

boiler

  and  removing  all 

horizontal joints.

We  recommend  that  an  annual  maintenance  service 
is carried out, preferably under a programmed service 
contract. The essential part of this service is a visual and 
functional check on the following components:
• reduction motor
• smoke expulsion fan
• smoke sensor
• heat-exchanger fan
• ignition sparkplug
• resettable pellet thermostat
• room temperature sensor
• pressostat
• motherboard
• fuse protecting panel - motherboard

The use of aggressive detergents or 
thinners can damage the surfaces of the 

boiler

. Before using any detergent it 

is advisable to try it on a small section out of sight 
or contact the Authorized Assistance Centre 
for information regarding the product.

Содержание CentroPelet ZVB 16

Страница 1: ...UE CentroPelet ZVB 16 20 24 32 TURZVB 01 2017 ENG Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for installation use and maintenance of...

Страница 2: ...an reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly must be performed by authorized...

Страница 3: ...e every responsibility derived from improper use of the boiler from incorrect use by the user from un authorized modifications and or repairs from the use of replacement parts that are not original fo...

Страница 4: ...upervision or instruction concerning use of the appliance Do not use the boiler as a ladder or scaffold Do not put clothes to dry on the boiler Any clothes hangers and suchlike must be kept a suitable...

Страница 5: ...ammable maintain a minimum distance of 10 cm at the rear A di 40 cm at the side B and 150 cm at the front If the room contains objects which are believed to be particularly delicate such as drapes sof...

Страница 6: ...ess steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue pip...

Страница 7: ...must be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics...

Страница 8: ...Water amount in stove Autonomy Power supply Power consume at nominal power Dimensions width depth height Net weight kW kg h mm Kg h W mm kg lit Model mm V Hz ZVB 16 4 29 14 4 1 02 3 37 89 11 87 87 80...

Страница 9: ...t weight kW kg h mm Kg h W mm kg lit Model mm V Hz ZVB 20 5 21 17 51 1 2 3 88 92 13 88 82 80 50 65 50 54 16 5 230 50 100 300 610x785x1240 250 ZVB 24 Technical characteristics CentroPelet ZVB 20 24 80...

Страница 10: ...in stove Autonomy Power supply Power consume at nominal power Dimensions width depth height Net weight kW kg h mm Kg h W mm kg lit Model mm V Hz ZVB 32 6 34 29 14 1 43 6 48 91 64 90 65 100 60 85 60 38...

Страница 11: ...e LED is on when the parameter UT01 on the menu is not on OFF and the weekly or daily programming are set SET LED SYMBOL DESCRIPTION The LED starts up every time the boiler is loading pellets The LED...

Страница 12: ...the water temperature press the key only once You will see the words Set H2o blinking on the upper display You will read the water temperature on the lower display To set the room temperature press th...

Страница 13: ...ntrol panel for example 18 C and a sufficient shut down time has elapsed the boiler will come back on automatically and continue running until again reaching 20 C Regardless of the operation of the ex...

Страница 14: ...ystem through the inlet pipe causing a phenomenon of oxygen that is highly damaging to life of the boiler To prevent this phenomenon it is possible to apply the following measures lower the speed of t...

Страница 15: ...adjustment UT06 From 00 00 to 23 50 with 10 minute steps Boiler first shutdown time adjustment UT07 Between on off for days from 1 to 7 Week day selection first time activation UT08 From 00 00 to 23...

Страница 16: ...day Day 6 Saturday Day 7 Sunday OFF Heating timer thermostat disabled UT07 Week day selection Press button o select the days of the week Press button to enable ON or disable OFF the pellet boiler boil...

Страница 17: ...Other fuses to protect the electronic boards are to be found on the boards themselves Reduction motor if the motor stops the boiler continues to function until the flame goes out for lack of fuel and...

Страница 18: ...or Check the water sensor is connected Contact an Authorized Assistance Center ALAR ALAR ALAR ALAR ALAR ALAR COOL ALAR ALAR ALAR ALAR SERV Hot temp The smokes temperature exceeds 280 C Smokes sensor f...

Страница 19: ...of pellets in the tank or because the motor reducer for pellets loading got broken The boiler continues working until the pellets left in the brazier ends You will then read the words Alar No Fire on...

Страница 20: ...idual combustion in the contact zone between the edges of the crucible and the support surface on the door crucible Parts Everyday Every 2 3 days Every week Every 15 days Every 30 days Every 60 90 day...

Страница 21: ...Check every 60 90 days Cleaning the interior baffle smoke fan compartment Inside the compartment where there is the ash tray there is a second cover fixed by the cockerels which gives access to the co...

Страница 22: ...s a fuse holding compartment which is located underneath the supply socket With a screwdriver open the cover of the fuse holding compartment and replace the fuse if necessary 3 15 AT delayed type Plug...

Страница 23: ...lar Do not touch the boiler body and the various components do not approach the door it could cause burns Do not touch the exhaust fumes Do not perform any type of cleaning Do not dump the ashes Do no...

Страница 24: ...other non original The operations marked in bold type must be carried out by specialised personnel Any kind of tampering or unauthorized substitution of non original of the boiler can be hazardous to...

Страница 25: ...closed properly or gaskets worn 5 Boiler temperature is too high 6 Unsuitable pellets 7 Low pellet feed rate 8 Combustion chamber dirty 9 Smoke outlet obstructed 10 Smoke extraction motor failed 11 Pr...

Страница 26: ...k the motor and capacitor and replace if necessary 3 Replace electronic board 4 Replace the control panel In the automatic position the boiler always runs at full power 1 Room thermostat set to maximu...

Страница 27: ...of the boiler 1 It been set to a value of thermostat too high 2 It was set too much power to the implant 1 Lower the temperature in the boiler 2 Reduce the value of operating power The boiler goes in...

Страница 28: ...2 fax 385 40 372 621 Centrometal d o o shall not be responsible for possible incorrect data caused by printing errors or error made in transcription and all figures and diagrams are for explanatory pu...