System pressure safety
The system pressure is checked electronically and needs
to be between 0,5 and 2,3 bar. If this is not the case,
the pellet boiler signalises an alarm and shows the
words “
A l a r P r e s s
” on the display.
Press” on the display. Check the system pressure keeping
the key
pressed for some seconds. You will read the
bar value on the display.
The safety valve keeps anyway the value under 2,5 bar
letting the exceeding water flow out automatically.
Intervention in case of danger
In case of fire, disconnect the power supply, use a fire
extinguisher in accordance with, and if necessary, call the
fire department and then contact an authorised qualified
technical assistance
Failed light-up
If the flame does not light up during the switching on or if
the smokes temperature does not reach a suitable value
in the foreseen time gap, the
boiler
switches off and you
will read the words “
A l a r N o A c c
” on the display.
Press
the key “On/Off” to reset the alarm. Wait until the cooling
phase is completed, clean the brazier and start a new
light-up.
Switching off while working
The
boiler
suddenly switches off while working (for
example because it has run out of pellets in the tank or
because the motor reducer for pellets loading got
broken). The
boiler
continues working until the pellets left
in the brazier ends. You will then read the words “
A l a r
N o F i r e
” on the display and the
boiler
switches off. Press
the key “On/Off” to reset the alarm. Wait until the cooling
phase is completed. Clean the brazier and start a new
light-up.
These alarms remind you that the brazier must be
cleaned and installed correctly before switching
on the
boiler
.
There is no power supply
In the event of a power drop longer than one minute,
the
boiler
can exhaust some smoke in the room: this
causes no risks.
As soon as you have the power supply again, the
boiler
will have the words “
C o o l F i r e
” on the
display. After completing the cooling phase, the
boiler
will start up again automatically according to the
previous settings.
Manual restart thermostat
Do not attempt to start the
boiler
before the required time or it may
get blocked. If this occurs, switch off
the
switch on the back of the pellet boiler for 1
minute, set it on again and wait 10 minutes
before starting the
boiler
again.
The power socket where the
boiler
is
connected should be fitted with “earth
connection complying with regulations in
force.” The Manufacturer shall not be held respon-
sible for damage to things or people resulting from
negligent installation.
Restart
Water