GB
In the event of a working defect, the system informs the
user about the type of failure occurred.
The following table summarises the alarms, kind of problem
and possible solution:
Upper
display
Lower
display
Kind of failure
Solution
ALAR
FAN
FAIL
ALAR
DEP
FAIL
ALAR
SIC
FAIL
ALAR
SIC
FAIL
ALAR PRESS
Smokes extractor blo-
cked or broken
Obstructed flue
Pellets tank overheating
Too high water tempera-
ture
The system pressure
does not reach 0,5 bar
or exceeds 2,3 bar
Contact
an
authorised
qualified technical assi-
stance
Clean the flue or check
there are no obstructed
grids near the smokes
exhaust
Re-set the safety thermostat
for pellets on the back of the
stove. If the problem occurs
again, contact an authorised
qualified technical assistance
Re-set the safety thermostat
for water on the back of the
stove. If the problem occurs
again, contact an authorised
qualified technical assistance
Reduce the system
pressure
Charge the system
ALAR
NO
ACC
- the pellet boiler stove
cannot start up
- this is the first light-up
Fill in the tank with pellets
Start up again
ALAR
NO
FIRE
- the pellet boiler stove
switched off while wor-
king
Fill in the tank with pellets
ALAR
SOND
FUMI
The smokes sensor is
broken or not connected
to the pcb
Contact an authorised and
qualified technical assi-
stance
ALAR
HOT
H20
The water temperature
exceeds 90°C. The cir-
culating pump is blocked
or there is no water in the
hydraulic system
Check the power supply
on the pump.
Check limestone does not
block the pump impeller
ALAR
SOND
H20
The water sensor is not
connected
There is a short circuit on
the water sensor
Check the water sensor is
connected
Contact an authorised qua-
lified technical assistance
ALAR
HOT
TEMP
The smokes temperature
exceeds 280°C
Smokes sensor failure
Contact an authorised qua-
lified technical assistance
COOL
FIRE
There is no power sup-
ply
As soon as the power sup-
ply is back, the stove starts
a cooling cycle. After com-
pleting the cycle it starts
working automatically
Regular checks should be carried out by the user, who
should only contact the Technical Assistance Service if
no solution is found.
SERV
The stove has worked
for 1300 hours.
Supplementary
maintenance required
Contact an authorised
qualified technical assi-
stance
Size: 12V
The remote control (Pict. 3) s used to adjust water tempe-
To start the pellet boiler stove, press keys and si-
multaneously. The pellet boiler stove will automatically en-
ter the starting phase.
Press keys and to adjust water temperature, and
use keys and to adjust operating power.
To turn off the pellet boiler stove, hold down keys and
simultaneously. “OFF” will be shown on the Pellet
boiler stove display.
To replace the 12 volt battery located on the back of the
Replace the battery observing the correct polarity (Pict. 4).
Pict. 3
Pict. 4