Turn off the pellet boiler stove by
pressing button , for a couple
of seconds until
1((
is shown
on the upper display.
REMARKS:
In case of repeated ignition lock-outs, while pellets are fed
regularly, there may be a problem caused by a failing elec-
tric glow plug. In this case, while you wait for a technician,
the pellet boiler stove can be manually started by using so-
lid fuel cubes (firelighters).
Manual starting procedure
:
-
To set the room temperature,
press the key twice: you
will see the words
5'6#4+#
blin-
king on the lower display. You will
read the set temperature on the
upper display.
Use the keys and to
change the value.
Use the keys and
to increase and reduce the
wished value.
Water temperature range: 30°C – 80 °C
Procedure to turn off the pellet boiler stove
Pellet feeding will stop immediately but the pellet boiler stove
will continue working until the accumulated heat is fully consu-
med, turning itself off automatically after
approx. 30 minutes.
The heating power is set by the
keys and
. A heating po-
wer
at Po 9 is suggested
during
the first working hours of the stove.
To set the water temperature
press the key only once. You
will see the words
5CR*M
blin-
king on the upper display. You
will read the water temperature
on the lower display.
REMARKS:
The pellet boiler stove is fitted with
an automatic device that allows clea-
ning the brazier after a given period of
time: when this time is detected, the
stove fire automatically reduces and
27.(+4'
is shown on the display. After
some minutes, the pellet boiler stove
will start working regularly.
Room temperature range: 7°C – 40 °C
WARNING
Do not unplug the power plug to turn off the pellet boiler sto-
ve; wait until the automatic shutdown cycle finishes: the con-
tinuous operation of the fumes extraction fan is normal and
may indicate that the stove is still hot. In the event of low tem-
peratures, it might happen that the stove - although switched
off - starts the smokes fan and circulator for some minutes in
order to prevent ice formation on the pipes of the system. in
the event there is a power drop, the main board will exhaust
the smokes residuals as soon as the power supply is back on.
In order to do that, the main board will increase the speed and
show the words “Cool FIRE” on the display. As soon as the co-
oling phase has been completed, the stove will automatically
start up working as it was set before the power drop.
CAUTION!
Do not use any flammable liquid to start the stove.
During the reload phase, do not bring the bag of pellets
in contact with the hot pellet boiler stove.
Room temperature setting
Working power and water temperature settings
Содержание CentroPelet ZV14
Страница 11: ...Notes ...