Dear Customer,

Congratulations on your purchasing an pellet boiler stove! We would like to remind you that pellet boiler stoves are the 
most innovative heating solution generated by the most advanced technology, characterised by high-quality manufactu-
ring as well as a simple and elegant design. Ideal for any type of room, these products contribute to comfort thanks to the 
cosy heat that only flames can radiate. 
This manual will help you use your pellet boiler stove properly. Therefore, read it carefully and thoroughly before using the unit.
Stoves are fuelled only by wood pellets, up to 6mm in diameter. They are fitted with an exchanger that allows reaching a heat 
yield of approx. 90%. 
Pellet boiler stoves are fitted with a timer-thermostat that ensures an autonomous management of the stove as it can be pro-
grammed to turn on and off up to 4 times per week. Pellet boiler stoves take the heat to the radiators in the heating system, 
with a thermal power that is adjusted according to the space to be heated: just set the heating system water temperature 
manually. Recommended temperature: between 60° and 75°.
Pellet boiler stove also heats the room where it is installed  through a natural convection air- system. 
Pellet boiler stoves have been equipped with highly advanced automatic devices and control and safety systems that ensure 
efficient and practical operation.
Installation and maintenance operations should be carried out by qualified personnel, in compliance with the laws in force 
and according to the indications specified by the Manufacturer.
This use and maintenance manual is an integral part of the product.
Before using, installing or servicing the product, read the indications contained in this manual carefully.
This pellet boiler stove should only be used for the intended use it has been designed for. Therefore, the user shall be 
responsible for any damage to people, animals or things resulting from misuse of the product.

Installation should be carried out by qualified personnel, who will be fully responsible for installing the product 
and ensuring its proper operation. The Manufacturer shall not be responsible in case of installation by unqualified 
personnel or without complying with the general warnings and installation instructions.

For safety reasons, it is advisable to remember that:

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

฀ ฀

In the event of a fire, disconnect the power supply, use an extinguisher and call the fire fighters if necessary. After that con-
tact the Authorised Assistance Centre.

After unpacking the unit, check all the parts are in good conditions and that no item is missing. Otherwise, contact the 
dealer from which you purchased your pellet boiler stove.
Before installing the unit, it is advisable to clean all the ducts and pipes in the system very carefully in order to remove any 
scales that may affect the stove correct operation.
Whenever the pellet boiler stove is not used for a long time, it is advisable to carry out the following operations:

฀ ฀

฀ ฀

฀ ฀

฀ ฀

The pellet boiler stove extraordinary maintenance should be carried out at least once a year. This operation should be 

฀ ฀

฀ ฀ ฀

CAUTION!

The first two or three times your pellet boiler stove is started, fumes emitted by the varnish may cause unpleasant smells 
due to hardening. Therefore, it is advisable to air the room properly, and avoid staying long in front of the pellet boiler 
stove.

Содержание CentroPelet ZV14

Страница 1: ...NG TECHNIQUE CentroPelet ZV14 TUZS 4 2014 ENG Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for regulation use and maintenance of pellet stove ...

Страница 2: ...use and maintenance manual is an integral part of the product Before using installing or servicing the product read the indications contained in this manual carefully This pellet boiler stove should only be used for the intended use it has been designed for Therefore the user shall be responsible for any damage to people animals or things resulting from misuse of the product Installation should be...

Страница 3: ...prox Kg 130 80 mm 50 mm 3 4 220V 50Hz 90 W 350 W only start phase 17 kg Weight Flue pipe diameter Air intake pipe diameter Power Supply Min electrical input Max electrical input Hopper capacity Pict 1 Aproximative dimensions mm ...

Страница 4: ...e upper display and the system delivery water temperature will be shown on the lower display If the flame does not start up correctly within 10 minutes the pellet boiler stove jams you will read the words 4 on the upper display and the words 01 blinking on the lower di splay Wait 10 minutes until the cooling phase is completed open the door empty the brazier and start a new light up Pict 2 Prelimi...

Страница 5: ...the water temperature on the lower display REMARKS The pellet boiler stove is fitted with an automatic device that allows clea ning the brazier after a given period of time when this time is detected the stove fire automatically reduces and 27 4 is shown on the display After some minutes the pellet boiler stove will start working regularly Room temperature range 7 C 40 C WARNING Do not unplug the ...

Страница 6: ...ivation The meaning of the user parameters are explained in detail below UT01 Heating timer thermostat enabling and disabling and current hour setting This parameter is used to set the current day of the week or to deactivate the set programming Press buttons and to select the desired value as shown in the following table Upper Display MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 OFF Example ...

Страница 7: ...ay MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Lower display In the following example the pellet boiler stove is only star ted on Saturdays and Sundays off 1 off 2 off 3 off 4 off 5 on 6 on 7 Confirm and continue with key If the stove is controlled by an external thermostat when the thermostat reaches the preset temperature 1 6 4 will be shown on the pellet boiler stove display CAUTION the r...

Страница 8: ...20 The water temperature exceeds 90 C The cir culating pump is blocked or there is no water in the hydraulic system Check the power supply on the pump Check limestone does not block the pump impeller ALAR SOND H20 The water sensor is not connected There is a short circuit on the water sensor Check the water sensor is connected Contact an authorised qua lified technical assistance ALAR HOT TEMP The...

Страница 9: ...se is completed clean the brazier and start a new light up Switching off while working The stove suddenly switches off while working for example because it has run out of pellets in the tank or because the motor reducer for pellets loading got broken The stove continues working until the pellets left in the brazier ends You will then read the words J P 0M GPC on the display and alarm Wait until th...

Страница 10: ...uster to avoid ash to discharge To activate this function press the key and then the key you will read the words PUL STUF cleaning of the stove on the display In order to stop the fan you just need to press the key for a longer time waiting that a cleaning phase is completed 255 seconds EVERY DAY remove and clean the brazier Pict 6 FROM TIME TO TIME clean the exchanger every two days When the stov...

Страница 11: ...Notes ...

Страница 12: ...l figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE Centrometal d o o Glavna 12 40306 Macinec Croatia central tel 040 372 600 fax 040 372 611 service tel 040 372 622 fax 040 372 621 Notes ...