For tech nical q uestions,  please call 1 -8 8 8 -8 6 6 -5 7 9 7 .

Item 61718 

        

SAFET

Y

OP
ER

ATION

M

AINTENAN

C

E

SETU
P

Air Source

1. 

Nev er connect to an air source th at 

is capable of  ex ceeding  2 0 0  psi.

  

Over pressurizing the tool may cause 

bursting, abnormal operation, 

breakage of the tool or serious injury 

to persons.  Use only clean, dry, regulated 

compressed air at the rated pressure or within the 

rated pressure range as marked on the tool.  

Always verify prior to using the tool that the air 

source has been adjusted to the rated air pressure 

or within the rated air-pressure range.

2. 

Never use oxygen, carbon dioxide, combustible 

gases or any bottled gas as an air source 

for the tool.

  Such gases are capable of 

explosion and serious injury to persons.

 SAV E THESE INSTR U CTIONS.

Sy m bols and Specif ic Saf ety  Instructions

Sy m bol Def initions

Sy m bol

P roperty  or statem ent

n

o

No-load speed

. . . / m in

Revolutions or reciprocation per minute

P SI

Pounds per square inch of pressure

f t-lb

Foot-pounds of torque

BP M

Blows per minute

CFM

Cubic Feet per Minute flow

SCFM

Cubic Feet per Minute flow 

at standard conditions

Sy m bol

P roperty  or statem ent

NP T

National pipe thread, tapered

NP S

National pipe thread, straight

WARNING marking 

concerning Risk of Eye Injury.  

Wear ANSI-approved eye protection.

WARNING marking concerning Risk of 

Hearing Loss.  Wear hearing protection.

WARNING marking concerning 

Risk of Respiratory Injury.  Wear 

NIOSH-approved dust mask/respirator.

WARNING marking concerning 

Risk of Explosion.

Содержание 61718

Страница 1: ......

Страница 2: ...oderate injury Addresses practices not related to personal injury IMP OR TANT SAFETY INSTR U CTIONS INSTR U CTIONS P ER TAINING TO A R ISK OF FIR E ELECTR IC SHOCK OR INJU R Y TO P ER SONS W AR NING W...

Страница 3: ...d or against the body is unstable and is able to lead to loss of control 2 Do not f orce th e tool Use the correct tool for the application The correct tool will do the job better and safer at the rat...

Страница 4: ...an air source for the tool Such gases are capable of explosion and serious injury to persons SAV E THESE INSTR U CTIONS Sy m bols and Specif ic Saf ety Instructions Sy m bol Def initions Sy m bol P r...

Страница 5: ...hose is ruptured 8 Use this tool with both hands only Using tools with only one hand can result in loss of control 9 Do not lay the tool down until it has come to a complete stop Moving parts can gra...

Страница 6: ...ions Maximum Air Pressure 90 PSI Air Inlet 1 4 18 NPT Rated Speed 7 000 RPM Average Air Consumption 5 CFM 90 PSI Arbor Chuck Capacity 1 2 Rated speed at stated maximum air pressure Excess air pressure...

Страница 7: ...such as a coupler plug and quick coupler will make operation more efficient but are not required W AR NING TO P R EV ENT SER IOU S INJU R Y FR OM ACCIDENTAL OP ER ATION Do not install a f em ale q ui...

Страница 8: ...on A Air Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Cou...

Страница 9: ...For vibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to poin...

Страница 10: ...Trigger for clockwise forward tool operation 2 Push the Control Valve back so that the end of the Valve protrudes from the back of the Housing for counterclockwise reverse tool operation 3 Adjust air...

Страница 11: ...the regulator up to the maximum air pressure rating of this tool CAU TION TO P R EV ENT INJU R Y FR OM TOOL OR ACCESSOR Y FAILU R E Do not ex ceed th e tool s m ax im um air pressure rating If the to...

Страница 12: ...l oil Oth er lubricants m ay dam ag e th e m ech anism and m ay be h ig h ly f lam m able causing an ex plosion Cleaning Maintenance and Lubrication Note These procedures are in addition to the regula...

Страница 13: ...qualified technician clean and lubricate mechanism Install in line filter in air supply as stated in Setup Air Supply Severe air leakage Slight air leakage is normal especially on older tools 1 Cross...

Страница 14: ...ist and Diag ram P LEASE R EAD THE FOLLOW ING CAR EFU LLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUF...

Страница 15: ...Page 15 For tech nical q uestions please call 1 8 8 8 8 6 6 5 7 9 7 Item 61718 SAFETY OP ER ATION MAINTENANCE SETU P Assem bly Diag ram...

Страница 16: ...ve limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage...

Отзывы: