IMPORTANT SAFETY INSTRUCTIONS 

 

 

SAVE THESE INSTRUCTIONS – This manual contains important instructions for models Aurora Vista 650 
IEC / 850 IEC / 1200 IEC / 2200 IEC that should be followed during installation and maintenance of the 
UPS and batteries. 

 

 

This  product  is  specially  designed  for  PCs  and  it  is  not  recommended  for  use  in  any  medical 

equipment, life-supporting system and other specific important equipment. 

 

Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS.  

 

Do not attach a power strip or surge suppressor to the UPS. 

 

Do not plug the UPS into its own output. 

 

Connection  to  any  other  type  of  receptable  other  than  two-pole,  three-wire  grounded  receptacle 

may result in shock hazard as well as violate local electrical codes. 

 

To reduce risk of overheating the UPS, do not cover the UPS´ cooling vents. 

 

This unit intended for installation in a controlled environment (temperature controlled, indoor area 

free  of  conductive  contaminants).  Avoid  installing  the  UPS  in  locations  where  there  is  standing  or 

running water or excessive humidity and do not use it in any of the following environments: 

o

 

Any area with combustible gas, corrosive substance or heavy dust. 

o

 

Any  area  with  extraordinarily  high  or  low  temperature  (above  40˚C  or  below  0˚C)  and 

humidity of more than 90%. 

o

 

Any area exposed to direct sunshine or near any heating apparatus. 

o

 

Any area with serious vibrations. 

o

 

Outdoor. 

 

The  utility  power  outlet  shall  be  near  the  equipment  and  easily  accessible.  In  the  event  of  an 

emergency, press OFF button and disconnect the power cord from the AC power supply to properly 

disable the UPS. 

 

The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore 

do  not  allow  liquids  or  any  foreign  object  to  enter  the  UPS.  No  water  containers  (such  as  a  water 

glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such 

dangers as electric shock. 

 

Please do not use the UPS in excess of the rated load capacity. 

 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

 

Risk of electric shock, do not attempt to disassemble the unit. No user serviceable parts inside. Refer 

servicing to qualified service personnel. 

 

If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the 

utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge. 

 

EN 

Содержание Aurora 650

Страница 1: ...1 Line Interactive UPS Aurora Vista 650 Aurora Vista 850 Aurora Vista 1200 Aurora Vista 2200 Quick Start Guide EN EN ...

Страница 2: ...ng environments o Any area with combustible gas corrosive substance or heavy dust o Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 o Any area exposed to direct sunshine or near any heating apparatus o Any area with serious vibrations o Outdoor The utility power outlet shall be near the equipment and easily accessible In the event of an em...

Страница 3: ... in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Icon Φ on the rating label stands for phase symbol This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen During the installation of this equipment it should be assured ...

Страница 4: ...more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR function DC Cold start function Green Power Function for energy saving Auto restart while AC recovery Provides AC Overload protection RJ11 RJ45 in out LAN Modem Phone line protection 3 Package Contents You should hav...

Страница 5: ...ode it will display as below And the mark will flicker every 1second When in battery mode it will display as below And the mark will flicker every 1second Note If I P V 40V input voltage will display 000 When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode When in fault mode it will display as below FAULT character and 0 charact...

Страница 6: ...ge 13 2V 11 5V battery voltage 12 5V 13 2V battery voltage 13 5V Battery voltage 12 5V Battery voltage 13 5V 2B model battery definition Battery Level Battery bar Indication Battery mode Other mode Battery voltage 22V Battery voltage 25 4V 22V battery voltage 23V 25 4V battery voltage 26 4V 23V battery voltage 25V 26 4V battery voltage 27V Battery voltage 25V Battery voltage 27V 4 When over load t...

Страница 7: ...7 Back Panel 650 IEC 850 IEC 1200 IEC 2200 IEC AC input 4 IEC outlet RJ11 Modem phone line protection AC input 6 IEC outlet USB port RJ45 LAN Modem phone line protection Breaker ...

Страница 8: ... contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Connect to Utility and Charge Plug in the AC input cord to the 2 pole 3 wire grounded wall outlet For the best results we suggest charging the battery at least 6 hours with no load no electrical devices such as...

Страница 9: ... Connect from OUT outlet to the computer with another phone line cable V Connect USB Cable To monitor the UPS status such as unattended UPS shutdown and start up by using bundled software please connect the UPS and PC with USB cable included VI Turn On Off the Unit Turn on the UPS unit by pressing the power switch Turn off the UPS unit by pressing again the power switch Do not attach a power strip...

Страница 10: ...stallation on your PC Connected by USB to a PC or notebook the Software enables communication between the UPS and the computer The UPS software monitors the status of the UPS shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Network enabling users to manage their system more effectively Upon AC failure or UPS battery low UPS takes all necessary actions with...

Страница 11: ...8 hours 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not pressed 3 Press the power switch again Alarm buzzer beeps continuously when AC supply is normal Overload of the UPS Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low ...

Страница 12: ...rge overcharge and overload protection ENVIRONMENT Humidity 0 90 RH 0 to 40 C non condensing Noise Level Less than 40dB 45dB Software Monitoring Software WinPower included BATTERY Type Number 12V 7Ah x 1 12V 9Ah x 1 12V 7Ah x 2 12V 9Ah x 2 Charging Time 6 hours recover to 90 capacity Backup Time est 100W 16 min 20 min 30 min 50 min PHYSICAL LCD Indicator LCD display Outlet 4 x IEC outlets 6 x IEC ...

Отзывы: