background image

 

©2021 Lowell Manufacturing Co. UPS9AC-1000 (X-Rev 5/6/21)  

 

 

Model UPS9AC-1000 

 

Uninterruptible Power Supply 
User & Installation Manual

 

power

TM

Содержание UPS9AC-1000

Страница 1: ... 2021 Lowell Manufacturing Co UPS9AC 1000 X Rev 5 6 21 1 Model UPS9AC 1000 Uninterruptible Power Supply User Installation Manual power TM ...

Страница 2: ... 3 Transportation 3 Preparation 3 Installation 3 Operation 3 Maintenance service and fault 4 Installation and setup 5 Rear panel view 5 Setup the UPS 6 Operations 8 Button operation 8 LED panel 9 Troubleshooting 11 Storage and Maintenance 12 Specifications 13 Obtaining Service 14 Limited Warranty 15 ...

Страница 3: ... housing Installation Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output receptacles Place cords in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output receptacles The UPS can be operated by any individuals with no previous experience Connect the UPS system only to a gro...

Страница 4: ...stwatches rings and other metal objects b Use only tools with insulated grips and handles C Wear rubber gloves and boots d Do not lay tools or metal parts on top of batteries e Disconnect charging source and load prior to installing or maintaining the battery When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could...

Страница 5: ...e that nothing inside the package is damaged Please keep the original package in a safe place for future use Rear panel view 1KL 1 AC input power cord 2 Output receptacle connect to mission critical loads 3 Programmable outlets connect to non critical loads 4 USB serial communication port 5 ROO RPO function connector 6 Intelligent slot ...

Страница 6: ... RS 232 port To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the USB port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for Relay card When installing with SNMP card in t...

Страница 7: ... insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the internet 1 Go to the website http www power software download com 2 Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts t...

Страница 8: ...ass mode is enabled via software 1KL View Button Function On Mute Button Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS Mute the alarm When the UPS is on battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur Off Enter Button Turn off the UPS P...

Страница 9: ...el Green On Battery Mode LED2 Yellow Flashing LED4 to LED7 indicate battery capacity during battery mode LED4 battery voltage 26V LED5 battery voltage 24 5V LED6 battery voltage 23V LED7 battery voltage 21V Green On Low battery LED7 Green On LED3 Red On Battery replacement LED3 Red Flashing Fault LED3 Red On On off status of output receptacles LED 8 indicating on off status of general output recep...

Страница 10: ...rm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds UPS Status Indicators AC Mode Green LED lighting Battery Mode Yellow LED flashing Fault Red LED lighting Off mode charging Green LED flashing ...

Страница 11: ...tery connection is wrong Please re connect battery wires with correct polarity The alarm is sounding twice every second and red LED is flashing UPS is overloaded Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UPS and restart it The mains ...

Страница 12: ...as been exceeded the batteries must be replaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Model Storage Temperature Recharge Frequency Charging Duration UPS9AC 1000 25 C 50 C Every 3 months 1 2 hours 50 C 55 C Every 2 months...

Страница 13: ...RY Battery type Sealed maintenance free lead acid Battery quantity size 4 6V 290W Typical recharge 6 hours to 90 PHYSICAL Dimensions W x D x H 17 2 x 18 8 x 1 7 in Weight 28 lbs Line cord 5 ft 5 15P Receptacles 3 NEMA 5 15R ENVIRONMENT Operating temperature 32 104 F 0 40 C Altitude 11 500 ft above sea level APPROVALS UL cUL RoHS WARRANTY 3 years electronics 3 years battery warranty USA and Canada ...

Страница 14: ...rmation and if possible help solve the problem over the phone In the event that the unit requires factory service the representative will issue you a Return Material Authorization number RMA If you are returning the UPS for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the Lowell representative about obtaining a...

Страница 15: ...ring Company or a Lowell Manufacturing Company approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions A...

Отзывы: