Lowell power UPS9AC-1000 Скачать руководство пользователя страница 14

 

©2021 Lowell Manufacturing Co. UPS9AC-1000 (X-Rev 5/6/21)  

 

14 

Obtaining Service 

If the UPS requires service:

 

1.

 

Use the TROUBLESHOOTING section in this manual to eliminate obvious causes. 

2.

 

Verify there are no circuit breakers tripped. 

3.

 

Call your dealer for assistance. If you cannot reach the dealer or if they cannot resolve the problem, call Lowell 
Manufacturing  Company  at  (800)  325-9660.  Technical  support  inquiries  can  also  be  made  by  email  to 
[email protected]. Please have the following information available BEFORE calling: 

 

Your name and address. 

 

The serial number of the unit. 

 

Where and when the unit was purchased. 

 

All of the model information about your UPS. 

 

Any information on the failure, including LEDs that may or may not be illuminated. 

 

A description of the protected equipment, including model numbers if possible. 

 

A representative will ask you for the above information and, if possible, help solve the problem over the 
phone. In the event that the unit requires factory service, the representative will issue you a Return 
Material Authorization number (RMA). 

 

If you are returning the UPS for service, please follow these procedures: 

1.

 

Pack  the  UPS  in  its  original  packaging.  If  the  original  packaging  is  no  longer  available,  ask  the  Lowell 
representative about obtaining a replacement set of packaging material. It is important to pack the UPS properly 
in order to avoid damage in transit. Never use Styrofoam beads for a packing material. 

2.

 

Include a letter with your name, address, daytime phone number, RMA number, a copy of your original sales 
receipt, and a brief description of the problem. 

3.

 

Mark  the  RMA  number  on  the  outside  of  all  packages.  Lowell  Manufacturing  cannot  accept  any  package 
without the RMA number marked on the outside of the boxes. 

4.

 

Return the UPS by insured, prepaid carrier to the address provided by the Lowell representative. 

5.

 

Refer to the Warranty statements in this manual for additional details on what is covered. 

 

 

 

Содержание UPS9AC-1000

Страница 1: ... 2021 Lowell Manufacturing Co UPS9AC 1000 X Rev 5 6 21 1 Model UPS9AC 1000 Uninterruptible Power Supply User Installation Manual power TM ...

Страница 2: ... 3 Transportation 3 Preparation 3 Installation 3 Operation 3 Maintenance service and fault 4 Installation and setup 5 Rear panel view 5 Setup the UPS 6 Operations 8 Button operation 8 LED panel 9 Troubleshooting 11 Storage and Maintenance 12 Specifications 13 Obtaining Service 14 Limited Warranty 15 ...

Страница 3: ... housing Installation Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output receptacles Place cords in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output receptacles The UPS can be operated by any individuals with no previous experience Connect the UPS system only to a gro...

Страница 4: ...stwatches rings and other metal objects b Use only tools with insulated grips and handles C Wear rubber gloves and boots d Do not lay tools or metal parts on top of batteries e Disconnect charging source and load prior to installing or maintaining the battery When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could...

Страница 5: ...e that nothing inside the package is damaged Please keep the original package in a safe place for future use Rear panel view 1KL 1 AC input power cord 2 Output receptacle connect to mission critical loads 3 Programmable outlets connect to non critical loads 4 USB serial communication port 5 ROO RPO function connector 6 Intelligent slot ...

Страница 6: ... RS 232 port To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the USB port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for Relay card When installing with SNMP card in t...

Страница 7: ... insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the internet 1 Go to the website http www power software download com 2 Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts t...

Страница 8: ...ass mode is enabled via software 1KL View Button Function On Mute Button Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS Mute the alarm When the UPS is on battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur Off Enter Button Turn off the UPS P...

Страница 9: ...el Green On Battery Mode LED2 Yellow Flashing LED4 to LED7 indicate battery capacity during battery mode LED4 battery voltage 26V LED5 battery voltage 24 5V LED6 battery voltage 23V LED7 battery voltage 21V Green On Low battery LED7 Green On LED3 Red On Battery replacement LED3 Red Flashing Fault LED3 Red On On off status of output receptacles LED 8 indicating on off status of general output recep...

Страница 10: ...rm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds UPS Status Indicators AC Mode Green LED lighting Battery Mode Yellow LED flashing Fault Red LED lighting Off mode charging Green LED flashing ...

Страница 11: ...tery connection is wrong Please re connect battery wires with correct polarity The alarm is sounding twice every second and red LED is flashing UPS is overloaded Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UPS and restart it The mains ...

Страница 12: ...as been exceeded the batteries must be replaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Model Storage Temperature Recharge Frequency Charging Duration UPS9AC 1000 25 C 50 C Every 3 months 1 2 hours 50 C 55 C Every 2 months...

Страница 13: ...RY Battery type Sealed maintenance free lead acid Battery quantity size 4 6V 290W Typical recharge 6 hours to 90 PHYSICAL Dimensions W x D x H 17 2 x 18 8 x 1 7 in Weight 28 lbs Line cord 5 ft 5 15P Receptacles 3 NEMA 5 15R ENVIRONMENT Operating temperature 32 104 F 0 40 C Altitude 11 500 ft above sea level APPROVALS UL cUL RoHS WARRANTY 3 years electronics 3 years battery warranty USA and Canada ...

Страница 14: ...rmation and if possible help solve the problem over the phone In the event that the unit requires factory service the representative will issue you a Return Material Authorization number RMA If you are returning the UPS for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the Lowell representative about obtaining a...

Страница 15: ...ring Company or a Lowell Manufacturing Company approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions A...