When finished sanding, release the 

10. 

Air Valve Lever (28) and allow the Air 

Reciprocating Sander to slow to a 

stop completely before laying the tool 

down. 
Disconnect air supply hose, put a few 

11. 

drops of pneumatic tools lubricating 

oil in the air inlet of the tool.  Connect 

the air supply hose.  Run the tool for 

a few seconds only.
Disconnect the air hose from the Air 

12. 

Regulator Assembly (30).
Wipe off the Air Reciprocating Sander 

13. 

with a clean, soft cloth before stor-

ing the tool inside, out of the reach of 

children. 

user-MAintenAnce 

instructions

  Procedures not specifically 

explained in this manual 

must be performed only by a 

qualified technician.

 

to preVent 

serious injurY 

FroM AccidentAl 

operAtion: 

turn off the tool, detach the 

air supply, safely discharge 

any residual air pressure in 

the tool, and release the 

throttle and/or turn the switch 

to its off position before 

performing any inspection, 

maintenance, or cleaning 

procedures.

to preVent serious 

injurY FroM tool 

FAilure: do not use 

damaged equipment.  if 

abnormal noise, vibration, 

or leaking air occurs, have 

the problem corrected before 

further use.
to preVent explosion:  

lubricate the tool only 

with specified lubricants.  

lubricate the air inlet 

using only pneumatic tool 

oil.  lubricate the internal 

mechanism using only 

white lithium grease.  other 

lubricants may damage the 

mechanism and may be 

highly flammable, causing an 

explosion.

cleaning, Maintenance, and 

lubrication

note:

  These procedures are in addition to 

the regular checks and maintenance 

explained as part of the regular op-

eration of the air-operated tool.

daily - Air supply Maintenance: 

1. 

Every day, perform maintenance on 

the air supply according to the com-

ponent manufacturers’ instructions.   

The lubricator’s oil level needs to be 

maintained and the moisture filter 

must be regularly drained.   Perform-

ing routine maintenance on the air 

supply will allow the tool to operate 

more safely and will also reduce wear 

on the tool. 

 note:  Always follow 

all Manufacturer’s safety warnings 

and procedures for the air com-

pressor and components you are 

using with this reciprocating Air 

reciprocating sander.

Содержание 98189

Страница 1: ...1 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyr...

Страница 2: ...rdous situation which if not avoided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or mod...

Страница 3: ...ff before connecting to the air sup ply Do not carry the tool with your finger on the Air Valve Lever 28 or connect the tool to the air supply with the Air Valve Lever 28 depressed on Remove adjusting...

Страница 4: ...before using Many accidents are caused by poorly maintained tools Use only accessories that are h identified by the manufacturer for the specific tool model Use of an accessory not intended for use wi...

Страница 5: ...r WARNING Some dust created by 2 power sanding sawing grinding drill ing and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other re...

Страница 6: ...s to ensure medical problems are not being caused or worsened from use Pregnant women or people who have impaired blood circulation to the hand past hand injuries ner vous system disorders diabetes or...

Страница 7: ...d to turn the Air Reciprocating Sander ON and OFF by depressing ON or releasing OFF See Figure 1 Figure 2 Air Regulator Assembly 30 Air Regulator Knob 36 2 The Air Regulator Assembly 30 regulates amou...

Страница 8: ...tic Tool Oil to the airline connection be fore operation Add a few more drops after each hour of continual use Attach an air hose to the compres 2 sor s air outlet Connect the air hose to the air inle...

Страница 9: ...il repaired Use hook and loop sand paper not 1 supplied for this Air Reciprocating Sander Large sheets can be eas ily cut to size The correct size sand paper is 2 7 16 L X 3 4 W The recommended air ho...

Страница 10: ...ing procedures To prevent serious injury from tool failure Do not use damaged equipment If abnormal noise vibration or leaking air occurs have the problem corrected before further use To prevent explo...

Страница 11: ...ave qualified technician clean and lubricate 6 mechanism Install in line filter in air supply as stated in Initial Set Up Air Supply Replace all vanes 7 Housing heats during use Incorrect lubrication...

Страница 12: ...Nut 1 ea 33 Nut 1 and Washers 2 34 Sanding Plate 1 35 Handle 1 36 Air Regulator Knob 1 PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly...

Страница 13: ...53 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not av...

Страница 14: ...or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including t...

Отзывы: