background image

Page 6

SKU 96364

For technical questions, please call 1-800-444-3353.

3. 

Push the Magazine Assembly back into the Brad Nailer and secure it with the Re-

lease Latch.

Testing the Single Sequential Safety Trip Mechanism

For greater safety and ease of operation, the Brad Nailer should only fire one time 

when both the Trigger (43) is pulled and Driver Guide (51) is depressed.  To test this func-

tion:  
1. 

Disconnect the Brad Nailer from the air supply.

2. 

Empty all Brads out of the Magazine Assembly (73).

3. 

Ensure that the Trigger (43) and Driver Guide (51) move freely, without sticking.

Caution Always point the Brad Nailer at a piece of scrap material when testing.
4. 

The Brad Nailer should not fire if the Driver Guide is not depressed against the 

workpiece.

5. 

Connect the air supply to the Air Inlet (72) and set the regulator at 90 PSI.

6. 

Test the Brad Nailer by depressing the Driver Guide against a piece of scrap mate-

rial.  The Brad Nailer should not 

fire.  If it does fire, stop work im-

mediately and have the tool re-

paired by a qualified service 

technician.

7. 

Further test the Brad Nailer by 

pulling the Brad Nailer back 

from the piece of scrap material.  

The Driver Guide should always 

return to the original position.  

Squeeze the Trigger (43).  If the 

tool fires, stop work immediately 

and have the tool repaired by a 

qualified service technician.

8. 

Depress the Driver Guide against 

the scrap material and pull the 

Trigger.  The Brad Nailer should 

fire only once.  With the Trigger still held, lift the Brad Nailer and press it against the 

scrap material again.  The tool should not fire.  If the Brad Nailer fails to perform in 

the manner described above, stop work immediately and have the tool repaired by 

a qualified service technician.

Air Inlet 

(72)

Magazine 

Assembly 

(73)

Driver 

Guide (51)

Trigger 

(43)

Release 

Latch (67)

Figure 2

Содержание 96364

Страница 1: ...s Blvd Camarillo CA 93011 Visit our website at http www harborfreight com TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Copyright 2007 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions...

Страница 2: ...l need this manual for the safety warnings and precautions assembly oper ating inspection maintenance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Write the product s serial number in the back of the manual near the assembly dia gram or write month and year of purchase if product has no number K...

Страница 3: ...ables better control of the power tool in unexpected situations 8 Use safety equipment Always wear ANSI approved eye protection Dust mask nonskid safety shoes hard hat or hearing protection must be used for appropriate conditions Always wear ANSI approved safety goggles and a dust mask respirator when using performing maintenance or reloading this tool TOOL USE AND CARE 1 Use clamps not included o...

Страница 4: ...result in a risk of injury 2 When servicing a tool use only identical replacement parts Follow instruc tions in the Inspection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury SPECIFIC SAFETY RULES 1 Maintain labels and nameplates on the tool These carry important information If unr...

Страница 5: ...ed to the Brad Nailer See Figure 1 2 Wrap the 1 4 air connector not included with at least four turns of pipe thread seal tape before connecting to a 3 8 ID Air Source Hose not included 3 Set the air pressure on the compressor between 50 to 120 PSI The recommended setting is 90 PSI Do not exceed the maximum air pressure of 120 PSI The amount of air pressure used effects how deep the Brads will be ...

Страница 6: ...he regulator at 90 PSI 6 Test the Brad Nailer by depressing the Driver Guide against a piece of scrap mate rial The Brad Nailer should not fire If it does fire stop work im mediately and have the tool re paired by a qualified service technician 7 Further test the Brad Nailer by pulling the Brad Nailer back from the piece of scrap material The Driver Guide should always return to the original posit...

Страница 7: ...he Brad Nailer Do not allow children or bystanders in the area where the Brad Nailer is being used or worked on 1 When a Brad gets jammed in the Brad Nailer first disconnect the air supply and then disengage and empty the Magazine Assembly 2 Attempt to fire the Brad Nailer into a piece of scrap material to ensure it is prop erly disconnected and incapable of firing before beginning any work on the...

Страница 8: ... out of the reach of children 6 All maintenance service or repairs not listed in this manual should only be completed by a qualified service technician TROUBLESHOOTING Problem Solution Air leak near top of tool 1 Tighten all screws on the cylinder cover 2 Have a qualified service technician service the tool Tool does not work 1 Make sure the compressor is set between 50 120 PSI 2 Check all air con...

Страница 9: ...2 6x2 35 17 O ring 30x1 8 18 Cylinder 19 Cylinder Sealing Washer 20 O ring 20 5x2 21 Main Piston 22 Bumper 23 Gun Body 24 Rubber Washer Part Description 25 O ring 1 7x2 26 Pin 27 Safety Stand 28 Pusher Spring 29 Adjustable Nut 30 Lock Nut M4 31 Hex Nut M4 32 Spring 33 Steel Ball DW 2 34 Tip Stand 35 E ring d 6 36 Safety Tip 37 Rectangle Ring 38 Trigger Valve Seat 39 Trigger Valve Stem 40 Trigger V...

Страница 10: ...Page 10 SKU 96364 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM ...

Страница 11: ...90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal ac tivity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential...

Отзывы: