background image

Page 4

For technical questions, please call 1-888-866-5797.

Item 93755 

        

SA

FE

TY

OP
ERA

TI

O

N

MAINT

ENANC

E

SE

TUP

Specific Safety Instructions

1. 

This Drum Extractor is designed for use only 

with nonflammable, noncorrosive liquids.  This 

tool is also not designed for fuel transfer. 

2. 

Do not use the Drum Extractor on damaged 

or rusted barrels.

  Barrel must have a 

sealed lid.  This unit pressurizes the barrel to 

extract liquid and will only function properly 

and safely on closed, sealed barrels.

3. 

Stay within air pressure capacity.

  Never 

operate the Drum Extractor above 10 PSI.

4.  Only use with accessories rated to handle the 

forces exerted by this tool during operation.  

Other accessories not designed for the forces 

generated may break and forcefully launch pieces.

5.  Attach all accessories properly to the tool before 

connecting the air supply.  A loose accessory 

may detach or break during operation.

6.  Obey the manual for the air compressor 

used to power this tool.

7.  Install an in-line shutoff valve to allow 

immediate control over the air supply in an 

emergency, even if a hose is ruptured.

8. 

Disconnect air hose and release any 

built-up air pressure.

  Never service the 

Drum Extractor or disassemble with the air 

hose attached.  Always release any built-up 

air even after disconnecting hose.  Disconnect 

the Drum Extractor when not in use.

9.  Maintain product labels and nameplates.  

These carry important safety information.  

If unreadable or missing, contact 

Harbor Freight Tools for a replacement.

10. The warnings and precautions discussed in this 

manual cannot cover all possible conditions and 

situations that may occur.  It must be understood 

by the operator that common sense and caution 

are factors which cannot be built into this 

product, but must be supplied by the operator.

 SAVE THESE INSTRUCTIONS.

Содержание 93755

Страница 1: ...d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2022 by Harbor Freight Tools All rights...

Страница 2: ...ty warnings and instructions Failure to follow the warnings and instructions may result in serious injury Work Area 1 Keep the work area clean and well lit Cluttered benches and dark areas increase th...

Страница 3: ...essories or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally Turn off and detach the air supply safely discharge any residual air pressure and rele...

Страница 4: ...e tool before connecting the air supply A loose accessory may detach or break during operation 6 Obey the manual for the air compressor used to power this tool 7 Install an in line shutoff valve to al...

Страница 5: ...g concerning Risk of Hearing Loss Wear hearing protection WARNING marking concerning Risk of Respiratory Injury Wear NIOSH approved dust mask respirator WARNING marking concerning Risk of Explosion Sp...

Страница 6: ...ote For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual Note This air tool may be shipped with a protective plug cove...

Страница 7: ...onnected Note Air flow and therefore tool performance can be hindered by undersized air supply components The air hose must be long enough to reach the work area with enough extra length to allow free...

Страница 8: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Страница 9: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Страница 10: ...ached to Suction Tube B 5 Insert the Oil Filter 9 into the Inlet Plug 10 Then firmly screw the Inlet Plug onto the lower section of Suction Tube C Inlet Plug 10 Oil Filter 9 Suction Tube Coupler 7 Suc...

Страница 11: ...nd set its regulator to 10 PSI Do not exceed 10 PSI 4 Set the Regulator on the Drum Extractor up to 10 PSI Stay within air pressure capacity Do not operate the Extractor above 10 PSI Note The rate of...

Страница 12: ...spect the general condition of the Drum Extractor Check for loose hardware or housing misalignment or binding of moving parts cracked or broken parts any other condition that may affect its safe opera...

Страница 13: ...of the Drum Extractor is adjusted to compensate for the viscosity of the liquid being extracted Do not exceed maximum air pressure 6 Remove Drum Extractor from the barrel and check for blockages in t...

Страница 14: ...HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Record Product s Serial Number Here Note If product...

Страница 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 93755 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram 28 4 1 3 2 5 6 7 8 9 10 12 11 16 18 29 17 14 13 19 20 15 21 22 23 24 27 25 26...

Страница 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Отзывы: