background image

Page 5

For technical questions, please call 1-888-866-5797.

Item 93755 

        

SA

FE

TY

OP

ERA

TI

O

N

MAINT

ENANC

E

SE

TUP

Symbology

PSI

Pounds per square inch of pressure

CFM

Cubic Feet per Minute flow

SCFM

Cubic Feet per Minute flow 

at standard conditions

NPT

National pipe thread, tapered

NPS

National pipe thread, straight

WARNING marking 

concerning Risk of Eye Injury.  

Wear ANSI-approved eye protection.

WARNING marking concerning Risk of 

Hearing Loss.  Wear hearing protection.

WARNING marking concerning 

Risk of Respiratory Injury.  Wear 

NIOSH-approved dust mask/respirator.

WARNING marking concerning 

Risk of Explosion.

Specifications

Extractor Flow Rate

3.5 GPM @ 5 PSI • 7 GPM @ 7.5 PSI

Air Regulator

1/4" Mini (4 Port) w/Gauge

Push/Twist/Lock Adjust

0~22 PSI / 0~0.15

MPa

Discharge Size

3/4" I.D.

Suction Tube Size

1-1/4" O.D. x 40" Long

Bung Sizes

1-1/2" & 2" (both w/O-Rings)

Working Air Pressure

10 PSI

Air Inlet Size

1/4"-18 NPT w/Quick Disconnect

Air Valve Type

1/4" Ball Valve w/Swing Lever

Pressure Release Valve

1/4"-18 Brass w/Pull Ring

Содержание 93755

Страница 1: ...d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2022 by Harbor Freight Tools All rights...

Страница 2: ...ty warnings and instructions Failure to follow the warnings and instructions may result in serious injury Work Area 1 Keep the work area clean and well lit Cluttered benches and dark areas increase th...

Страница 3: ...essories or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally Turn off and detach the air supply safely discharge any residual air pressure and rele...

Страница 4: ...e tool before connecting the air supply A loose accessory may detach or break during operation 6 Obey the manual for the air compressor used to power this tool 7 Install an in line shutoff valve to al...

Страница 5: ...g concerning Risk of Hearing Loss Wear hearing protection WARNING marking concerning Risk of Respiratory Injury Wear NIOSH approved dust mask respirator WARNING marking concerning Risk of Explosion Sp...

Страница 6: ...ote For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual Note This air tool may be shipped with a protective plug cove...

Страница 7: ...onnected Note Air flow and therefore tool performance can be hindered by undersized air supply components The air hose must be long enough to reach the work area with enough extra length to allow free...

Страница 8: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Страница 9: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Страница 10: ...ached to Suction Tube B 5 Insert the Oil Filter 9 into the Inlet Plug 10 Then firmly screw the Inlet Plug onto the lower section of Suction Tube C Inlet Plug 10 Oil Filter 9 Suction Tube Coupler 7 Suc...

Страница 11: ...nd set its regulator to 10 PSI Do not exceed 10 PSI 4 Set the Regulator on the Drum Extractor up to 10 PSI Stay within air pressure capacity Do not operate the Extractor above 10 PSI Note The rate of...

Страница 12: ...spect the general condition of the Drum Extractor Check for loose hardware or housing misalignment or binding of moving parts cracked or broken parts any other condition that may affect its safe opera...

Страница 13: ...of the Drum Extractor is adjusted to compensate for the viscosity of the liquid being extracted Do not exceed maximum air pressure 6 Remove Drum Extractor from the barrel and check for blockages in t...

Страница 14: ...HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Record Product s Serial Number Here Note If product...

Страница 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 93755 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram 28 4 1 3 2 5 6 7 8 9 10 12 11 16 18 29 17 14 13 19 20 15 21 22 23 24 27 25 26...

Страница 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Отзывы: