3.1. Rigging
y
The installation of the fixture has to be built and constructed in a way that it
can hold 10 times the weight for 1 hour without any harming demolition. The
installation must always be secured with a secondary safety attachment, e.g. an
appropriate catch net. This secondary safety attachment must be constructed in
a way that no part of the installation can fall down if the main attachment fails.
y
When rigging, de-rigging or servicing the fixture staying in the area below the
installation place, on bridges, under high working places and other endangered
areas is forbidden. The operator has to make sure that the safety measure and
the machine’s technical installation is approved by an expert before taking into
operation for the first time and after changes before taking into operation an-
ther time. He has also to make sure that an expert approves safety measure and
the machine’s technical installation once a years.
IMPORTANT: Overhead rigging requires extensive experience, including (but not
limited to) calculating working load limits, installation material being used, and
periodic safety inspection of all installation material and the projector. If you
lack these qualifications, do not attempt the installation yourself, but instead
use a professional structural rigger. Improper installation can result in bodily
injury or property loss.
y
If the fixture shall be lowered from the ceiling or high joists, professional trussing
systems have to be used. The fixture must never be fixed swinging freely in the
room.
CAUTION: Use appropriate clamps to rig the fixture on the truss. Make sure that
the device is fixed properly! Ensure that the structure (truss) to which you are
attaching the fixtures is secure.
3.2. Heat
y
Do not use in a confined space. Always install the product in a location with
adequate ventilation, at least 20in (50 cm) from adjacent surfaces.
y
The apparatus should be located away from heat sources such as radiators,
stoves or other appliances that produce heat.
Don not use it when maximum ambient temperature is higher than 55°C. Work
temperature ranges from -30 to 55°C (from -22 to 131°F).