![CentoLight Moodwasher 4810WP Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/centolight/moodwasher-4810wp/moodwasher-4810wp_user-manual_2581678013.webp)
13
13
Moodwasher 4810WP User Manual
Eng
9 - l
uX
C
harT
Distance: 2m
Distance: 3m
Distance: 5m
Red
4000 lux
2400 lux
920 lux
Green
10000 lux
5300 lux
1960 lux
Blue
2100 lux
1000 lux
380 lux
White
10000 lux
5200 lux
2020 lux
RGBW
29300 lux
14300 lux
5350 lux
10 - T
roubleshooTing
Problem
Probable Cause(s)
Remedy
No response from fixture when
power is applies
No power to fixture
Check power cables
Check mains plug
Fixture does not reset correctly Electronic failure
Contact service technician*
No light, LED cuts out intermit-
tently, or burns out too quickly
LED missing or blown
Disconnect fixture and contact ser-
vice technician* fo LED replacement
Fixture or LED is too hot
Allow fixture to cool. If problem per-
sists, contact service technician*
Fixture resets but does not
respond correctly to controller
(DMX mode operation)
Controller not connected
Connect controller
Incorrect addressing of the
fixtures
Check address setting on fixture and
controller
Bad data link connection
Inspect cables and correct poor con-
nections and/or broken cables.
Conflict between tracking and
vector control
Eliminate scene cross-fade on
controller
Data link not terminated
Insert termination plug in output of
last fixture**
Defective fixture or 2 devices
transmitting on link
Bypass fixtures one at a time until
normal operation is regained: un-
plug both connectors and connect
them directly together
* To contact CentoLight service, see “12 - Warranty And Service” on page 15 or visit
** For instruction on how to install a DMX terminator, see “6.5. DMX Terminator” on page 11.
Содержание Moodwasher 4810WP
Страница 32: ...Ver 1 0 May 2022 www centolight com...