Measure the angular misalignment with a dial gauge (see Fig. 5-3).
Attach the dial gauge to the flange/hub/adapter (E/3/17).
Position the sensor of the dial gauge radially against flat surface at a
distance R.
Turn the flange/hub/adapter (E/3/17) with dial gauge and flywheel (B)
slowly by 360°.
The maximum dial gauge deflection must not exceed the value 2xS
w
at any
point. The permissible tolerance S
W max
should be taken from the table below.
Align the units (calculated deviation
≤∆K
W max
).
Permissible angular alignment tolerance:
∆K
W max
=
0.05°
Size
R
[mm]
S
W max
[mm]
50 - 64
225
0,20
66 - 70
250
0,22
71 - 72
300
0,26
75
325
0,28
78
355
0,31
80
405
0,35
81
425
0,37
82 - 85
505
0,44
88
590
0,51
90
630
0,55
Table 5-2 Permissible angular alignment tolerance