Unpacking

When unpacking, check to make sure the following parts are included. If any parts
are missing or broken, please call Harbor Freight Tools at the number on the cover
of this manual.

Operation

Controls and Indicators

Gas Detector

Power Adapter to
Charge Batteries

Charger Adapter
Connector

Earphone Connector

(Earphone not supplied)

On / Off Switch

Sensitivity  Adjust

Gas Sensor

mediately.  Calibration of the gas detector may be necessary by a qualified
technician. If the sensor fails calibration, have the sensor replaced by a quali-
fied technician.  Never use any source of ignition to test the accuracy of this
device.

Warning: The warnings, cautions, and instructions discussed in this instruction
manual cannot cover all possible conditions and situations that may occur. It
must be understood by the operator that common sense and caution are fac-
tors which cannot be built into this product, but must be supplied by the opera-
tor.

Содержание 93005

Страница 1: ...or Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 93005 IMPORTANT Performance of this tool may vary depending on variations in battery power or other cir cumstances Harbor Freight Too...

Страница 2: ...0 0 2 C D V 9 o t C A V 0 1 1 h c t i w S n O f f O r e d i l S t h g i e W s b l 5 5 1 Save This Manual You will need the manual for the safety warnings and precautions assembly instructions operating and maintenance procedures parts list and diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep the manual and invoice in a safe and dry place for...

Страница 3: ... to supplement the readings of the meter If your sense of smell detects gas that the meter does not get the meter calibrated im intended Do not modify this tool and do not use this tool for a purpose for which it was not intended 6 Check for damaged parts Before using any tool any part that appears damaged should be carefully checked to determine that it will operate properly and perform its inten...

Страница 4: ...pplied On Off Switch Sensitivity Adjust Gas Sensor mediately Calibration of the gas detector may be necessary by a qualified technician If the sensor fails calibration have the sensor replaced by a quali fied technician Never use any source of ignition to test the accuracy of this device Warning The warnings cautions and instructions discussed in this instruction manual cannot cover all possible c...

Страница 5: ...lower LED only 4 Perform a sample test In a safe area place the unit no closer than four inches from a known combustible gas i e cigarette lighter gas and check the display for a high reading Then move the unit where the air is clear The reading should go to low again 5 Adjust direction and place the Gooseneck Gas Sensor in the room where the atmosphere is to be tested Note Gases that are heavier ...

Страница 6: ...t area slide the On Off Switch to the Off position Maintenance 1 Recharge batteries when the LOW BAT LED lights Charge monthly whether the unit is used or not If after recharging the batteries the LOW BAT LED is still displayed replace the batteries with new ones of the same type Refer to the Specifications 2 If the unit is not functioning repeat the Gas Detection procedures as described on page 5...