DESCRIPTION AND TECHNICAL DESCRIPTION
3 EN
EN
1.0
DESCRIPTION AND TECHNICAL DESCRIP-
TION
1.1
DESCRIPTION
MIG/MAG welding professional generators, three-phase feeding,
forced ventilation, prepared for separated wire pulling set.
1.2
TECHNICAL DESCRIPTION
DATA PLATE
250 A
300 A
350 A
450 A / 450 A H
1.3
STANDARD EQUIPMENT
For models 250A, 450A and 450AH
- Earth cable
For models 300A and 350A
- Earth cable
- Digital instruments
1.4
DUTY CYCLE AND OVERHEATING
The duty cycle is the percentage of a 10 minute period for which
the welder can continue to weld without overheating. If the ma-
chine overheats, the welding current is shut off and the relative in-
dicator lamp illuminates. In this case, leave the machine to cool for
approx. 15 minutes and, before restarting, lower the welding cur-
rent value and relative voltage or reduce the work time.
Example: 400 A - 60% means working for 6 minutes at 400 A with
4 minutes rest time.
1.5
VOLT - AMPERE CURVES
The volt-ampere curves show the welder's maximum output cur-
rents and voltage (see page XVI - XVII).
PRIMARY
Three phase supply
230 V
400 V
Frequency
50 Hz
Effective consuption
15 A
8,5 A
Maximum consuption
27 A
15,6 A
SECONDARY
Open circuit voltage
18 ÷ 40 V
Welding current
35 A ÷ 250 A
Duty cycle 30%
250 A - 26,5 V
Duty cycle 60%
170 A - 22,5 V
Duty cycle 100%
140 A - 21 V
Protection class
IP 23
Insulation class
H
Weight
Kg. 77
Dimensions
mm 500 x 880 x 950
European Standards
EN 60974.1 / EN 60974.10
PRIMARY
Three phase supply
230 V
400 V
Frequency
50 Hz
Effective consuption
20 A
11,3 A
Maximum consuption
33 A
19 A
SECONDARY
Open circuit voltage
18 ÷ 45 V
Welding current
40 A ÷ 300 A
Duty cycle 35%
300 A - 29 V
Duty cycle 60%
230 A - 25,5 V
Duty cycle 100%
180 A - 23 V
Protection class
IP 23
Insulation class
H
Weight
Kg. 93
Dimensions
mm 500 x 880x 950
European Standards
EN 60974.1 / EN 60974.10
PRIMARY
Three phase supply
230 V
400 V
Frequency
50 Hz
Effective consuption
25 A
14,5 A
Maximum consuption
42 A
24 A
SECONDARY
Open circuit voltage
18 ÷ 46 V
Welding current
35 A ÷ 350 A
Duty cycle 35%
350 A - 31,5 V
Duty cycle 60%
270 A - 27,5 V
Duty cycle 100%
210 A - 24,5 V
Protection class
IP 23
Insulation class
H
Weight
Kg. 108
Dimensions
mm 500 x 880 x 950
European Standards
EN 60974.1 / EN 60974.10
PRIMARY
Three phase supply
230 V
400 V
Frequency
50 Hz
Effective consuption
35,5 A
20,5 A
Maximum consuption
60 A
34,5 A
SECONDARY
Open circuit voltage
19 ÷ 54 V
Welding current
51 A ÷ 450 A
Duty cycle 35%
450 A - 36,5 V
Duty cycle 60%
345 A - 31,3 V
Duty cycle 100%
270 A - 27,5 V
Protection class
IP 23
Insulation class
H
Weight
Kg. 140
Dimensions
mm 600 x 950 x 1050
European Standards
EN 60974.1 / EN 60974.10