15
33
71
6.2.2)
Insert into the spindle shaft, the
DPE
spacer required to activate the coolant system.
If it necessary to use an
APE...
adaptor, the bit must fi rst be fi tted into the corresponding
APE
adaptor and locked with the appropriate grub screw, then the
DPE
spacer inserted.
Note: Adaptors type APED… (e.g. APED 135/165) do not require use of DPE spacer.
6.2.3)
Insert the bit-spacer unit in the spindle shaft so that the two engaging dogs on the bit spigot
line up with the grub screws.
Press the bit-spacer unit home against the inner seat of the
spindle: this will enable the DPE spacer to open the coolant circuit
(see Fig. 10).
6.2.4)
Clamp the bit by fully tightening the two grub screws(18) using the 4 mm male allen key.
FIG. 10 – ASSEMBLING THE
BIT-SPACER UNIT
FIG. 9 – ASSEMBLING SPIRAL BITS
FIG. 11 – MANUAL SPINDLE ROTATION
07
18
DPE
*
DPE
Bits PE ...
(e.g. PE70)
Bits PE ...
(e.g. PE 190)
APE ...
* use only for APE, not required for
APED