2.9) Jaw replacement
Each tool is supplied with relevant jaws (see § 1).
Jaws can also be supplied separately, for replace-
ment proceed as follows:
– Push and turn clockwise the locking pin (9) so
that the jaws are released.
– Slide the jaws out of the top of the tool and insert
the new ones (see Fig. 5).
– Fully insert the locking pin (9) into the tool and
lock it by turning clockwise until the red lines are
aligned.
2.10) Using the battery charger
Carefully follow the instructions in the
battery charger manual.
The tool is supplied with a battery
charger complete with adapter type
CBA96-144 required for 9,6V bat-
teries (eg. CB9630H) (see Fig. 6).
With the adaptor removed, the same
charger may be used with the 14,4V
batteries (eg. CB1430H) common to
the other
Cembre
battery operated
tools.
Adapter CBA96-144
FIG. 6