background image

 

 

Important Information; see manual 

 

Conforms to European Union directives 

 

 

Controls and Indicators 

 

 

1. Sensor Tip Guard   

& Sensor (internal)

 

                              

2. Gooseneck Probe 

3. Alarm Light 

4. Ready Light (Power-On) 

5. Power ON/OFF Slide Switch 

6. Earphone Jack 

7. Tic Rate (Sensitivity) Adjustment 

8. Probe Clip 

   

9. Hand handle 

10. Batteries cover 

 

 

 

Instructions 

Switch on the gas-leak detector by sliding the 

ON/OFF button  and  the READY light is glowing. 

The Combustible Gas Leak Detector runs through a 

one-minute warm-up and self-zeroing  sequence 

when it is first turned on in fresh air. The alarm of 

the instrument may very loud without contact any 

Содержание GD-3300

Страница 1: ...User s Manual Combustible Gas Leak Detector Model GD 3300...

Страница 2: ...le Gas Leak Detector with one hand to detect presence of combustible gases Audible and visual indicators help pinpoint leak source Adjustable tic rate helps eliminate background gas concentration in c...

Страница 3: ...ombustible Gas Leak Detector as a result of a service call chances are someone has either smelled a combustible gas leak or someone has reason to believe gas may be leaking While your Combustible Gas...

Страница 4: ...ion As a matter of routine ventilate the area you plan to work in Ventilation will help ensure the gas does not accumulate in large volume where it can attain its Lower Explosive Limit LEL LEL Lower E...

Страница 5: ...e Switch 6 Earphone Jack 7 Tic Rate Sensitivity Adjustment 8 Probe Clip 9 Hand handle 10 Batteries cover Instructions Switch on the gas leak detector by sliding the ON OFF button and the READY light i...

Страница 6: ...be tip detects a combustible gas the tic rate will increase and the instrument sounds a warbling tone while the ALARM light As the concentration of gas increases so does the tic rate If the situation...

Страница 7: ...s In order to isolate the source of a leak you may need to move the wheel counter clockwise decreasing the sensitivity as the sensor moves closer Replacing the Batteries Replace your 1 5 volt size R14...

Страница 8: ...lly damaged To replace sensor 1 Turn the instrument off 2 Remove the upper tip guard by pressing straight up from the alignment notch that separates the two halves of the tip guard 3 This is a sturdy...

Страница 9: ...l Alarm Visible Audible at 10 LEL for Methane Can be calibrated for other concentrations or gases Warranty 1 year Operating Conditions To ensure accurate readings use it only when ambient air is withi...

Страница 10: ...o Natural Gas o Propane o Butane o Methane o Acetone o Alcohol o Ammonia o Steam o Carbon Monoxide not to quantify o Gasoline o Jet Fuel o Hydrogen Sulfide o Smoke o Industrial Solvents o Lacquer Thin...

Страница 11: ...10...