True RMS Autoranging Digital Multimeter
4-8. Diode Test
1. Set the function switch to the
CAP position.
Ω
2. Insert the black test lead banana plug into the negative
COM
jack and the red test lead banana
plug into the positive
jack.
Ω
3. Press the
MODE
button to indicate and V on the display.
4. Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to
0.700V. Reverse voltage will indicate “
OL
”. Shorted devices will indicate near 0V and an open device
will indicate “
OL
” in both polarities.