Series VC-50 / SVC-50 / MVC-50 / LVC-50

49-MCVC50EN03

USER´S MANUAL

1

1. INTRODUCTION

NOTE: These indicators are not allowed for the uses mentioned in paragraph 2a of the article 1

st

 of the

Directive 90/384/CE, therefore they are not valid for commercial transactions.

Weighing scales series VC-50 / SVC-50 / MVC-50 / LVC-50 offers precise, rapid and versatile weighing for
all uses, and includes item counting and weight check.

There are 3 scales in the series in this range with a platform size that starts at 350mm x 450mm and goes up
to 600mm x 800mm, with a capacity that ranges from 30 to 600 kg.

All keypads are sealed, membrane switches are colour-marked and displays are easy-to-read, large-sized
liquid crystal displays (LCDs). The LCDs are equipped with a backlight.

All models have manual zero setting, an acoustic alarm signal for preset weights, automatic tare, preset tare,
and accumulation function that permits calculations to be stored and retrieved as a total accumulated sum.

2. SPECIFICATIONS

Model

SVC-50

MVC-50

LVC-50

VC-50

Platform size

350mm x 450mm

420mm x 520mm

600mm x 800mm

--------------------

Range

30kg/60kg/150kg

60kg/150kg/300kg 300kg/600kg/1,000kg

--------------------

Resolution

1:15,000

Interface

RS-232 output (optional)

Stabilisation time

Normally 1 second

Operating
temperature

0°C - 40°C / 32°F - 104°F

Power supply

External CA adapter,  9V 800 mA

Calibration

External, automatic

Display

Digital 6 digit LCD display. Height of digits: 24 mm.

Manufacture
materials

ABS Plastic Indicator

Operating voltage
of load cell

Max 5V/150mA

Load cells

Up to four 350 ohm cells

Содержание LVC-50

Страница 1: ...VC 50 SVC 50 MVC 50 LVC 50 Ref 49 MCEVC50EN03 Rev 03 INDICATOR VC 50 SVC 50 MVC 50 LVC 50 WEIGHING SCALES User s Manual...

Страница 2: ......

Страница 3: ...ION OF KEYPAD 3 5 DISPLAY 4 6 OPERATION 4 6 1 MANUAL ZERO SETTING 4 6 2 SETTING THE TARE 4 6 3 SAMPLE WEIGHT 4 6 4 ITEM COUNTING 5 6 5 CHECKWEIGHER MODE 5 6 5 1 Operative 5 6 5 2 Setting the limits 6...

Страница 4: ......

Страница 5: ...asy to read large sized liquid crystal displays LCDs The LCDs are equipped with a backlight All models have manual zero setting an acoustic alarm signal for preset weights automatic tare preset tare a...

Страница 6: ...operate correctly Please unplug the scales immediately from the power supply Do not stack anything on the scales when they are not in use 3 2 INSTALLATION OF SERIES SVC 50 MVC 50 LVC 50 The column is...

Страница 7: ...eter or other function Press this key in the weighing mode to change to item counting mode In item counting mode this key changes to unit weight total weight and number of items Moves the active digit...

Страница 8: ...e some packaging on the platform and a weight value will appear Press to set the tare of the scales The weight that appeared on the display is saved as the tare value and that value is deducted from t...

Страница 9: ...nal when the weight situated on the platform matches or exceeds the values stored in the memory The memory stores values for a upper and lower limit 6 5 1 1 Checkweigher modes Weight check range The c...

Страница 10: ...e display will show ACC 1 and the total saved in the memory will be displayed for two seconds before returning to normal mode If the optional RS 232 interface is installed the weight will be sent to a...

Страница 11: ...ease the flashing digit Continue with the next digit and set the amounts as required When all the digits have been set press to save the value The display will return to the parameter that has just be...

Страница 12: ...when out of limits F5 Prt This activates the RS 232 print function when is pressed P Prt O continuous printing P Cont Series RS 232 connection with the RS 232 remote display After setting up the print...

Страница 13: ...epends on many different factors including the configuration of the backlight and operation Never use a damaged battery charger or battery Never short circuit the battery An accidental short circuit m...

Страница 14: ...nd count will be printed When the total weight stored in the accumulative memory is retrieved the outgoing format is GS 12 340kg GW for gross weight NT for net weight and unit of weight No 1 This numb...

Страница 15: ...After calibration the scales should be revised to check that calibration and linearity are correct If necessary repeat calibration and make sure that the scales are in a stable position before accept...

Страница 16: ...ions 1 2 5 10 20 50 C AP This display shows xxxxx to set up capacity After selecting the VC 50 SVC 50 MVC 50 LVC 50 will show the parameter for animal weighing scales if the external resolution that h...

Страница 17: ...C 50 LVC 50 Series The aforementioned manufacturer declares that the apparatus described herein complies with the requirements contained in Directive 89 336 CEE and 73 23 CEE and where applicable to t...

Страница 18: ......

Страница 19: ......

Отзывы: