Cely LVC-50 Скачать руководство пользователя страница 15

Series VC-50 / SVC-50 / MVC-50 / LVC-50

49-MCVC50EN03

USER´S MANUAL

11

10. CALIBRATION

Switch off the indicator.

Switch them on again and during the countdown from 9 to 0, press 

.

The display will show “CAL”. While the “CAL” is being shown, press 

 and 

 in the foregoing order in

order to enter calibration. The display will show “noLoAd”.

Remove any weight from the platform.  Press 

.

The display will show “LoAd”. Place the calibration weight on the scales. Press  

.

The display will show the last calibration weight used. If this weight is correct, continue by pressing 

. If it is

not correct, press the arrow keys to change the calibration weight value.  When it is correct, press 

.

If the calibration is correct the display will return to normal mode. If an error message appears, try to calibrate
the weight again since there may have been something that prevented the calibration from taking place
successfully.

If the problem continues, contact CELY or your supplier.
After calibration, the scales should be revised to check that calibration and linearity are correct. If necessary,
repeat calibration, and make sure that the scales are in a stable position before accepting any weight.

11. ERROR 

CODES

ERROR
CODES

DESCRIPTION

SOLUTION

- - - - -

Above the range

Remove the weight from the scales.
If the problem continues, contact your distributor or CELY
for assistance.

Err 1

Date set-up error

Enter the date using the correct format and logical values.
Format: yy.mm.dd

Err 2

Time set-up error

Enter the time using the correct format and logical values.
Format: hh.mm.ss.

Err 4

Zero set-up error

The scales were not correctly set-up in the zero range, or
they were switched on when  was pressed

.

Remove the weight from the scales and try again.
Use  

 to set the display to zero.

If the problem continues, contact your distributor or CELY
for assistance.

Err 6

A/D out of range

The A/D converter values are out of the normal range.
Remove the weight from the scales if there is excessive
weight and check that the platform is in position.
This error may indicate that the platform or electronics may
not be working correctly.

Содержание LVC-50

Страница 1: ...VC 50 SVC 50 MVC 50 LVC 50 Ref 49 MCEVC50EN03 Rev 03 INDICATOR VC 50 SVC 50 MVC 50 LVC 50 WEIGHING SCALES User s Manual...

Страница 2: ......

Страница 3: ...ION OF KEYPAD 3 5 DISPLAY 4 6 OPERATION 4 6 1 MANUAL ZERO SETTING 4 6 2 SETTING THE TARE 4 6 3 SAMPLE WEIGHT 4 6 4 ITEM COUNTING 5 6 5 CHECKWEIGHER MODE 5 6 5 1 Operative 5 6 5 2 Setting the limits 6...

Страница 4: ......

Страница 5: ...asy to read large sized liquid crystal displays LCDs The LCDs are equipped with a backlight All models have manual zero setting an acoustic alarm signal for preset weights automatic tare preset tare a...

Страница 6: ...operate correctly Please unplug the scales immediately from the power supply Do not stack anything on the scales when they are not in use 3 2 INSTALLATION OF SERIES SVC 50 MVC 50 LVC 50 The column is...

Страница 7: ...eter or other function Press this key in the weighing mode to change to item counting mode In item counting mode this key changes to unit weight total weight and number of items Moves the active digit...

Страница 8: ...e some packaging on the platform and a weight value will appear Press to set the tare of the scales The weight that appeared on the display is saved as the tare value and that value is deducted from t...

Страница 9: ...nal when the weight situated on the platform matches or exceeds the values stored in the memory The memory stores values for a upper and lower limit 6 5 1 1 Checkweigher modes Weight check range The c...

Страница 10: ...e display will show ACC 1 and the total saved in the memory will be displayed for two seconds before returning to normal mode If the optional RS 232 interface is installed the weight will be sent to a...

Страница 11: ...ease the flashing digit Continue with the next digit and set the amounts as required When all the digits have been set press to save the value The display will return to the parameter that has just be...

Страница 12: ...when out of limits F5 Prt This activates the RS 232 print function when is pressed P Prt O continuous printing P Cont Series RS 232 connection with the RS 232 remote display After setting up the print...

Страница 13: ...epends on many different factors including the configuration of the backlight and operation Never use a damaged battery charger or battery Never short circuit the battery An accidental short circuit m...

Страница 14: ...nd count will be printed When the total weight stored in the accumulative memory is retrieved the outgoing format is GS 12 340kg GW for gross weight NT for net weight and unit of weight No 1 This numb...

Страница 15: ...After calibration the scales should be revised to check that calibration and linearity are correct If necessary repeat calibration and make sure that the scales are in a stable position before accept...

Страница 16: ...ions 1 2 5 10 20 50 C AP This display shows xxxxx to set up capacity After selecting the VC 50 SVC 50 MVC 50 LVC 50 will show the parameter for animal weighing scales if the external resolution that h...

Страница 17: ...C 50 LVC 50 Series The aforementioned manufacturer declares that the apparatus described herein complies with the requirements contained in Directive 89 336 CEE and 73 23 CEE and where applicable to t...

Страница 18: ......

Страница 19: ......

Отзывы: