![Cellartec 1/2 Ton-SSL Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cellartec/1-2-ton-ssl/1-2-ton-ssl_installation-operation-and-care-manual_2580337013.webp)
- 12 -
6.
Use of the adjustable pressure control (if applicable for pump-down)
Suction pressure setting: Cut out=5 psig; Cut in=25 psig; Differential=20 psig
Head pressure setting: Cut out=230 psig; Cut in=150 psig; Differential=80 psig
It may need to adjust the setting in the field to get the right cycle time.
A. Single Control
Fig. 11 Single Adjustable Pressure Control
B. Dual Control
Fig. 12 Dual Adjustable Pressure Control
7.
Use of the encapsulated low pressure control (if applicable)
Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig