I I . O v e r v i e w
CellarPro Cooling Capacity*
Each of our cooling units includes sizing guidelines that are based on R19 insulation
throughout the cellar and 85F peak ambient temperatures outside the cellar.*
To find the BTUH output for each of our 1800 cooling units at 55F and 60F, and the
thermal loads for various-size cellars, refer to the table below. In order to maintain your
desired cellar temperature, the cooling unit’s BTUH output (at 55F or 60F inside the cellar)
must be greater than the load of your cellar, as shown in the body of the table.
*If your cellar is constructed with glass, or has uninsulated walls, or does not have a vapor
barrier),
the thermal load will be much higher than what’s shown in the table. In this
case, please .
visit
http://www.cellarprocoolingsystems.com/request-thermal-load
to
request a customized thermal load calculation for your cellar:
Cellar Temp
55 Degrees
60 Degrees
BTUH
1800QTL-ECX
1065
1154
BTUH
1800QT-ECX / EC
1380
1479
BTUH
1800XT-ECX / EC
1456
1558
BTUH
1800XTS-ECX / EC
1800XTSx-EC
1886
2031
Cellar Insulation –
Walls, ceiling & floor*:
R-12
R-19
R-12
R-19
Cellar Size
Ambient Temp
75 Degrees
1068
979
940
862
100 Cu Ft.
85 Degrees
1180
1046
1038
920
95 Degrees
1291
1114
1136
980
75 Degrees
1380
1253
1214
1103
200 Cu Ft.
85 Degrees
1538
1349
1353
1187
95 Degrees
1699
1446
1495
1272
75 Degrees
1700
1542
1496
1357
300 Cu Ft.
85 Degrees
X
1562
1672
1463
95 Degrees
X
1909
2003
1558
75 Degrees
X
1744
1690
1535
400 Cu Ft.
85 Degrees
X
1879
1888
1654
95 Degrees X X X
1773